7

Adjustments and servicing procedures

7.1

Air filter

1. Never remove the element while the compressor is running.
2. For minimum downtime, replace the dirty element with a new one.
3. Discard the element if damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. Release the snap clips of air filter (AF) and remove the dust trap and the air filter element.
Clean the trap. Discard the filter element.
3. Fit the new element and the cover.
4. Reset the air filter service warning.
For compressors equipped with an Airlogic² controller, see section
78
IMPORTANT
If you do not replace the filtering element when needed, permanent dirt will build up.
This reduces the air inflow to the compressor and could damage the oil separator and
the compressor.
Position of air filter
Instruction book
Service
menu.
2920 7101 24