5. System Startup

ELECTRICAL INSTALLATION TO BE PERFORMED BY A QUALIFIED ELECTRICIAN.
NOTE: Before starting up a unit, please make sure to refer to the Installation Requirements and Installation sections in this
Reverse Osmosis Instruction Manual before activation.
NOTE: Verify phase rotation from utility power supply to the R.O. System. This is critical for pump rotation to operate correctly.
Going to START mode (which starts the RO pump) before purging air from the pump can result in compromised
STEPS:
1.
Verify all drain ports are closed (membrane housing, carbon manifold, and RO tank)
Set the air regulator to 80 PSI. Slowly turn on the municipal water.
2.
3.
Press down the red air valve on top of the carbon housing to bleed air out of carbon housing.
4.
Release carbon tank air valve when water stream is developed from the red valves.
This process may take 10-15 MINUTES or more but it is a critical step to protect the system during initial start-up or
5.
after any maintenance during which air could enter any part of the system.
6.
Turn on the utility power from the wash to the R.O. System.
Turn 480VAC Main Disconnect switch to ON position (on the front of the enclosure)
7.
Press the power button on the HMI and wait until the Overview Screen appears. verify the HMI screen is the same as
8.
the one in fi g. 5 - 1. If not, please contact support@innovateITcarwash.com for more information.
Place the unit in MANUAL mode before moving to the air valve testing page (fi g. 5 - 1).
9.
System Startup
FOLLOW ALL LOCAL CODES
pump shaft seal or, if left long term, may require the pump to be replaced
WARNING!
CAUTION!
System Startup
|