4. Installation

DO NOT ATTEMPT TO REMOVE THE FILTER COVER IF THE PRESSURE IN THE HOUSING IS NOT ZERO. IF THE CAP IS
REMOVED WHILE THE UNIT IS PRESSURIZED, THE CAP COULD CAUSE SERIOUS INJURY OR DEATH.
Install an air supply to the ¼" push connector air regulator. (Verify air supply can supply 80-100PSI, 3CFM) and adjust
the air regulator to 80-100 PSI. (fi g. 4 - 1)
Customer Air Supply
80-100 PSI (1CFM)
Connect a municipal water inlet to RO 1.5" male NPT hose (verify municipal water can supply 25GPM for (Standard
Flow) or 35GPM for (High Flow) @ 40-60 psi.
Pressure Inlet Transducer
Line up the carbon block assembly to the RO unit and loosen groove coupling.
Slide the carbon block groove nipple to the groove coupling and tighten back up (fi g. 4 - 3)
Installation
fi g. 4 - 1 - Air regulator supply line
(PT1)
fi g. 4 - 2 - Pressure inlet transducer
WARNING!
Installation
|
17