AK-C8112 Medical Keyboard Wireless / Duo
The AK-C8112 series is a high quality, highly reliable hygiene keyboard line with full desktop layout. It is particularly
designed for the use at hospitals and by practitioners. The keyboards are sealed with a silicone membrane. They can
either be operated wireless or using a USB cable. The CleanFunction avoids sending keystrokes to your PC during
cleaning/disinfection. Please follow the instructions provided by your healthcare authorities for standard disinfection of
surfaces for reprocessing of the keyboard.
Installation:
1) Insert the 4 batteries in the orientation shown on the bottom of the keyboard.
2) Insert the USB-Wireless-Dongle into the USB port of your computer.
3) Now the keyboard is ready for wireless operation. Once you connect the keyboard with a USB cable, it will
change to corded operation. The Medical Keyboard Wireless Duo comes with a "USB-A to USB-C-cable" in the
box.
Delivery Content:
1x 2.4 GHz wireless keyboard
1x 2.4 GHz USB-Wireless-Dongle
1x Detachable USB cable (Duo version only)
Safety Note: The enclosed alkaline batteries are not designed to be recharged! Do not attempt to recharge!
Product Name
Product Number
Model
Medical Keyboard
AK-C8112-F series
CKW104R FCC ID: 2ACVU-CKW104RB IC ID: 30797-CKW104RB
USB-Wireless-Dongle AK-Z92-FU-SHARED DON2
Manufacturer:
Company:
Active Key GmbH
Address:
Brunnenaecker 6
91257 Pegnitz
Germany
Customer Service Europe:
Phone:
+49 9241-48337-0
Email:
info@activekey.de
Web:
www.activekey.de
Legal information FCC:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-
Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Legal information CANADA:
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development
Canada's license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
The product complies with the Canada portable RF exposure limit set forth for an uncontrolled environment and is safe for intended
operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible
from the user body or set the device to lower output power if such function is available.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et
Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) L'appareil ne doit pas produire de brouillage et (2) L'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
Le produit est conforme aux limites d'exposition pour les appareils portables RF pour Etats-Unis et le Canada établis pour un
environnement non contrôlé. Le produit est sûr pour un fonctionnement tel que décrit dans ce manuel. La réduction aux expositions RF
peut être augmentée si l'appareil peut être conservé aussi loin que possible du corps de l'utilisateur ou que le dispositif est réglé sur la
puissance de sortie la plus faible si une telle fonction est disponible.
CAN ICES-003(B) / NMB-003(B)
4x non-rechargeable alkaline batteries AAA
1x User Instruction, Customer Information
1x IP68 Sealing cap for battery compartment
FCC
IC
FCC ID: 2ACVU-D2
IC ID: 30797-D2
U.S. Responsible Party:
Company:
Cherry Americas LLC
Address:
5732 95th Ave., Suite 850
Kenosha, WI 53144
United States
Customer Service Americas:
Phone:
+1 800-510-1689
Email:
keyboardsupport@cherryamericas.com
Web:
www.cherryamericas.com
Legal information CE:
Hereby Active Key GmbH declares that the type of radio equipment used with the product models CKW104R (2.4 GHz Wireless
Keyboards) and DON2 (2.4 GHz USB-Wireless-Dongle) complies with the DIRECTIVE 2014/53/EU (RED). The full text of the EU
declaration of conformity is available at the following internet address:
As distributor of batteries, we have the following obligations under article 20 of directive 2006/66/EC:
1) Batteries can be returned free of charge after use in shops selling batteries.
2) End users are legally obliged to return used batteries.
3) Manufacturers of batteries are required to mark batteries with the symbol of the crossed-out wheeled bin before placing them on the
market for the first time.
The manufacturer of batteries shall label batteries containing more than 0.0005 % by mass of mercury, more than 0.002 % by mass of
cadmium or more than 0.004 % by mass of lead, before placing them on the market for the first time with the chemical
symbols of metals (Hg, Cd, Pb) in which the limit is exceeded. The characters are to be applied below the symbol.
Electrical and electronic equipment (EEE) is marked with the symbol of the crossed-out wheeled bin indicating the
requirement not to dispose of waste electrical and electronic equipment (WEEE) as unsorted municipal waste and to collect
such WEEE separately.
Final users of WEEE from private households shall be able to return WEEE as per EU country local regulations into established
collection facilities free of charge. Please consult your municipal waste department for detailed advice on separate collection of WEEE.
Please follow the rules of your local community on collection of used packaging.
Frequently Asked Questions (FAQ):
Usage of Medical Protective Gloves?
We recommend the use of nitrile gloves instead of latex gloves in the operation of our products. This reduces the risk of allergies and
avoids yellowing of the product by abrasion of the latex.
Detachable USB cable?
You may attach a USB cable with USB-Type-C connector to the keyboard by unlocking the sealing cap of the USB-Type-C port
opposed to the battery compartment and inserting the connector into the USB-C socket. The wireless interface will be disabled as soon
as the keyboard is connected to the PC. The Duo version has the cable included.
Energy saving mode?
The status LEDs show the status of Num Lock, Caps Lock and Scroll Lock as soon as those functions are enabled. In order to save
power, the status LEDs will turn off 15 seconds after the last key actuation.
How to determine the battery status?
The keyboard indicates low battery status by turning the LED "Clean" on for 5 seconds upon any actuation of keys. Please replace the
batteries as soon as possible. The keyboard will be turned off as soon as the low battery status reaches the related threshold. The turn
off point will be visualized with a blinking light using the first three LEDs.
How to activate/deactivate CleanFunction?
The key combination "Fn" + "Shift (Clean on/off)" activates and deactivates CleanFunction.
When the status LED "Clean" is flashing, it indicates that CleanFunction is activated. While activated, all keys are disabled, so you can
safely wipe, clean and disinfect the keyboard. The mode ends automatically after 60 seconds or by operating the key combination
again.
How to investigate a wireless connection problem?
1) Check whether CleanFunction is active and deactivate, if required.
2) Check whether the USB RF receiver is listed in the device manager of your Operating System (VID&PID=0x046A&0xC132).
3) Follow the pairing instructions (see below).
4) In case all previous steps do not resolve the problem, please consult with customer service.
How to pair a new USB-Wireless-Dongle with the device?
Note: This procedure is only required if you received a replacement USB-Wireless-Dongle. This is necessary if the original receiver
was lost or damaged. New pairing may also resolve a wireless connection problem.
1) Make sure any other USB-Wireless-Dongle(s) belonging to Active key wireless products in the near neighborhood are removed
from the USB ports. Do only connect the USB-Wireless-Dongle that shall get paired.
2) Initiate the pairing between USB-Wireless-Dongle and keyboard by depressing key combination "Fn" + "Esc".
3) The Scroll Lock status LED will flash in fast frequency for approx. 5 seconds until pairing process completed.
4) Test basic functionality of the keyboard. In case the pairing process failed, double check Step 1 and repeat.
5) In case the pairing process does not lead to success, please consult with Customer Service.
Specification:
Compatibility
All Operating Systems that support USB HID keyboards
Temperature Range
Storage -4 °F to 140 °F / -20 °F to +60 °C / Operation 32 °C to 122 °F / 0 °C to +50 °C
Chemical Resistance
Wipe disinfection according to the Cleaning and Disinfection Guidelines approved by EPA.
USB port keyboard
USB 2.0 Full Speed, Type-C socket
USB-Wireless-Dongle
USB 2.0 Full Speed, Type A connector, wireless range appr. 33 ft / 10 m
2402 MHz – 2475 MHz
Frequency-band Keyboard
2401 MHz – 2482 MHz
Frequency-band USB-Wireless-Dongle
Maximum transmission power / Rating
10 mW / 5.0 V/DC; max. 20 mA, SELV (Safety Extra Low Voltage)
Supply Voltage / Current Consumption
6 V by 4x non-rechargeable batteries AAA, typical 5 mA
Dimensions (incl. rubber cover)
Approx. 17.72 x 5.75 x 1.30 in / 450 x 146 x 33 mm
Weight
Approx. 1.6 lb / 740 g (without packaging)
Agency Approvals / Tests
CE, RoHS, FCC, IC, IEC 60601-1-2:2014*
*Test Report on EMC, No Medical Device acc.to US FDA requirements nor Health Canada's standards nor Regulation (EU) 2017/745.
All rights reserved. Copy or duplication, except for personal use, not permissible without specific prior written consent by Active Key
GmbH. Contents are subject to change without notice. Errors excepted. Copyright by Active Key GmbH.
Version 20231208_M-C8112-F/DE_EN
https://www.activekey.de/ce-doc/CE_DOC_RED_AK-C8112-F.pdf

Advertisement

loading

Summary of Contents for Cherry AK-C8112

  • Page 1 The AK-C8112 series is a high quality, highly reliable hygiene keyboard line with full desktop layout. It is particularly As distributor of batteries, we have the following obligations under article 20 of directive 2006/66/EC: designed for the use at hospitals and by practitioners.
  • Page 2 Wir empfehlen den Einsatz von Nitril- statt Latexhandschuhen bei der Bedienung unserer Produkte. Dies verringert Die AK-C8112 Produktreihe ist eine hochwertige und zuverlässige Hygiene-Funktastatur mit Desktop Layout. Sie ist das Allergierisiko und vermeidet eine Gelbverfärbung des Produkts durch Abrieb des Latex.