Procedure
5. Removing the Neutralizer
(1) Remove the screw holding the metal
clamp on the top of neutralizer
(2) Remove the 3 spring clamps on the
hoses of the neutralizer. 1 will be right
below the SS HE and 2 will be on the
neutralizer (you will need a needle
nose pliers to open spring clamps)
(3) Pull hoses off where clamps were
removed
(4) Lift up on neutralizer and pull out and
set aside
6. Remove Water Pipes Inside Unit
(1) Remove "C" Clamp on top of foam
covered pipe going into SS HE
(2) Remove "C" Clamp on bottom of
foam covered pipe going into Flow
Sensor
(3) Remove Pipe and set aside
Diagram
Page 5