OPERATING AND MAINTENANCE MANUAL

PROBLEM SOLVING

PROBLEM
The shaft does not rotate
Performance Drop
The tool vibrates
abnormally
The shaft does not stop
despite the start lever is
not pressed
CAUSE
Start lever tool not fully
pressed
The pressure or the capacity
of the line air alimentation is
inadequate or nil
Temperature too low
Tool failure
Position of the inverter
incorrect
Start lever tool not fully
pressed
The pressure or the capacity
of the line air alimentation is
inadequate or nil
Absence of lubrication
Dirty filter
Position of the inverter
incorrect
Tool failure
The tool is not well supported
to the screw
The accessories are not
connected properly
The accessories are worn
Tool failure
Start lever jammed
ATEX RANGE
REMEDY
Press the start lever
Check the line of air
alimentation
Operate in an environment
with higher temperature
Contact an authorized service
center
Replace the inverter of
rotation
Press the start lever
Check the line of air
alimentation
Read the instructions and
lubricated the tool
Clean the filter
Replace the inverter of
rotation
Contact an authorized service
center
Rest well the insert on the
screw-head
Connect correctly accessories
Replace the accessories
Contact an authorized service
center
Disconnect the power supply