TECHNICAL DATA

DESCRIPTION
Portable pneumatic impact wrench.
INTENDED USE
Tool for assembling threaded connection
elements.
LUBRICATION
Impact
mechanism
(Molykote® BR2 Plus)
Pneumatic motor lubrication: Oil for pneumatic
tools
ENVIRONMENTAL CONDITIONS
Operating temperature: from -5°C to +45°C
Storage temperature: from -5°C to +45°C
Air humidity: <80%
Max altitude: 2000m above sea level

SYSTEM COMPONENTS

See figure Fig.1.

GENERAL WARNINGS

L Fit a standard male compressed air quick
coupling to the threaded hole.
L Use a supply hose with an internal diameter
of at least 13 mm.
L Supply
only
with
pollutant-free compressed air.
L If possible, apply a supply filter, which must
be cleaned regularly.
lubrication:
Grease
dehumidified
and
COMPRESSED AIR SUPPLY
Maximum permissible pressure: 7.6 bar
Use pressure: 6.3 bar
L The compressed air must be free from
contaminants. Periodically check that there
are no leaks in the connection pipe and
sleeve through which GAS or DUST can
enter inside the impact wrench.
L Compressed air must have a maximum
particulate concentration of 0.1 mg/m3, dew
point +3°C and maximum oil concentration
0.01 mg/m3(ISO 8573-1:2010).
L Use a supply system that complies with the
pressure values indicated (max. 10% more
than the maximum value indicated) using a
pressure reducer supplied by a system that
complies with the current safety standards.
L Maximum surface temperatures: 85°C.
L Ensure earthing using a suitable spiral
compressed air hose (or similar) and with
an electrical resistance of the material lower
than 1GigaOhm.