Paoli DP 217 ATEX Operating And Maintenance Manual page 16

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
ATEX RANGE
USER GUIDE
L Fit the handle
(see figure
L If you have mistakenly used a higher torque
than that required:
• in case of tightening, replace the bolt and
reform the thread on which you screwed
it, due to yielding;
• in case of unscrewing, replace the bolt
anyway and check the thread on which
you have screwed it.
MANAGING THE CONTROLS
L Right rotation (screwing): Translate "T" the
inverter to the left and press "P" the starting
lever
(see figure Fig.3-A and figure
ASSEMBLY OF ACCESSORIES
Always disconnect the pneumatic impact wrench
from the power supply before replacing an
accessory. Always use accessories suitable for the
task to be performed and compatible with the
limits of the category indicated on the inside cover.
L "Drive without Hole and Ring": Insert the
accessory "A" in the impact wrench drive,
with an axial pressure
ENGLISH
16
OPERATING AND MAINTENANCE MANUAL
Fig.5).
Fig.3-C).
(see figure
Fig.4-A).
L If you used a lower torque, retighten with an
impact wrench of the correct torque, to avoid
the risk of unsafe tightening.
L Avoiding operating at a higher pressure
than required will result in energy saving,
less noise and reduced wear on the impact
wrench.
L Always use an impact wrench with the
tightening torque corresponding to that
required by the application.
L Left rotation (unscrewing): Translate "T" the
inverter to the right and press "P" the starting
lever
(see figure Fig.3-B and figure
L "Drive with Hole and Ring": Insert the
accessory "A" in the impact wrench drive,
with an axial pressure, and connect using
the pin "S" and the retaining ring "R"
figure
Fig.4-B).
Fig.3-C).
(see