Download Print this page

Control 4 C4-SW101-Z-W Installation Manual page 3

Advertisement

Wireless Fireplace
Switch Installation
Guide
Supported Models
C4-FS101-Z-W Wireless Fireplace Switch (White)
C4-FS101-Z-B Wireless Fireplace Switch (Black)
C4-FS101-Z-A Wireless Fireplace Switch (Almond)
This device requires a neutral AC connection.
Specifications and Supported Fixtures
This Control4® Wireless Fireplace Switch operates independently or as part of a
Control4® home automation system to enable intelligent lighting control. It installs in a
standard wall box using typical wiring standards and communicates with other devices
through a wireless RF (radio frequency) connection.
Power:
120 VAC +/-10% 50/60 Hz
300 mW when off
850 mW when on
Supported Load
30 VDC 8.3A
Types and Ratings:
Operating
All load ratings are based on an ambient temperature of
25 degrees Celsius.
Temperature:
Volume:
5.0 Cubic inches
Communications:
ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel, spread
spectrum radio
Warnings & Considerations
WARNING!
Install in accordance with all national and local electrical codes.
WARNING!
Improper use or installation can cause SERIOUS INJURY,
DEATH or LOSS/DAMAGE OF PROPERTY.
WARNING!
If you are unsure about any part of these instructions, consult a
qualified electrician.
WARNING!
Use this device only with copper or copper clad wire. This product
has NOT been approved for use with Aluminum wiring.
IMPORTANT!
Use or modification of this product in a manner not expressly
approved by Control4 voids your warranty. Further, Control4 is NOT liable for
any damage incurred with the misuse of this product. See "Limited 2 Year
Warranty."
IMPORTANT!
The range and performance of the wireless control system is
highly dependent on the following: (1) distance between devices; (2) layout of
the home; (3) walls separating devices; and (4) electrical equipment located
near devices.
Installation Instructions
1
TURN OFF POWER by switching off the circuit breaker or
removing the fuse and test that power is off before wiring!
2
Identify your wiring application (refer to the appropriate diagram
in "" on the back page).
"Single-Pole (with power source at wall box) - see Figure 1
"3-Way (with power source at wall box) - see Figure 2
3
Prepare wires by removing pre-cut
insulation from the appropriate fireplace
switch leads. Wire insulation should be
stripped back 5/8 of an inch from the wire
end (as shown).
4
Connect the fireplace switch wires to the
wall box wires using wire nuts according to the
relevant wiring diagram. See "Sample Wiring
Configurations."
5
Mount fireplace switch into wall box by partially
securing the wall box screws attached to the fireplace
switch. Ensure that the word "Top" on the fireplace
switch frame is facing up. Bend wires in a zigzag
pattern so that they easily fold into the wall box.
WARNING!
Ground the Wireless Fireplace Switch
in accordance with the National Electric Code (NEC) requirements. Although
the fireplace switch's aluminum yoke plate and green ground wire are directly
bonded together inside the fireplace switch, DO NOT rely solely upon the yoke
plate's contact with a metal wall box for adequate grounding. Use the fireplace
switch's ground wire to make a secure connection to the safety ground of the
electrical system.
IMPORTANT!
Not grounding this product according to the preceding may
result in an installation less immune to damage caused by electrical
disturbances, such as lightning, and void the warranty.
6
If you are using the Control4 push-on (screw-less) wall plate that shipped with
your fireplace switch:
a.
For a single-gang scenario, attach the black plastic sub-plate using the
provided sub-plate screws.
IMPORTANT!
Tighten the screws until the back side of the metal yoke plate
is even with the wall surface, but no farther. Over-tightening can damage the
fireplace switch and cause mechanical malfunction. Do NOT use a power
screw driver to install this device as this may lead to over-tightening.
b.
If you are installing in a multi-gang scenario, only partially tighten the
mounting screws, leaving about 1/8 of an inch gap between the wall and the
yoke plates prior to attaching the black plastic sub-plate. This allows each
device in a multi-gang scenario to conform to the sub-plate, creating a single
assembly. Secure the multi-gang sub-plate to all devices using the provided
sub-plate screws. Then secure the assembly by tightening the wall box
screws the remaining 1/8 of an inch. Do not over-tighten any of the screws
or you will misalign the flat plane of the multi-gang wall plate.
c.
With the wall plate's removal slot facing down, push the wall
plate onto the fireplace switch's black plastic sub-plate.
7
If you are using a Decora-style screw-on wall plate:
a.
Do not attach the fireplace switch's black plastic sub-plate
b.
Align the fireplace switch to the wall box and fasten with screws.
c.
Fasten the wall plate to the fireplace switch with screws.
8
Turn ON power at the circuit breaker or replace fuse from fuse
box.
9
Test the fireplace switch to see if it is working properly. See
"Operation and Configuration" for specific instructions.
Sample Wiring Configurations
Single-Location Scenario—Power Source at Wall Box
NOTE: This device will not function without a neutral AC connection.
To wire the switch for a Control4 single-location scenario in which the
power is first routed to the wallbox, connect together and cap with a
wire nut the wires indicated in the following table:
Fireplace Switch
Wires in the Wall Box
Wires
From Power Source
To Fireplace
White (neutral)
White (neutral)
None
Orange (load)
None
White (load)
Orange (load)
None
Black (load)
Black (hot)
Black (hot)
None
Green (ground)
Green (ground)
Green (ground)