Download Print this page
Dakota Digital HLY-3191 Manual

Dakota Digital HLY-3191 Manual

Round air pressure

Advertisement

Quick Links

(weather and vibration resistant for exposed environments)
Wiring:
GND
-
PWR
-
DIM
-
SND
-
Mounting:
The Series II gauge requires a round hole 2-1/16" in diameter. It should be inserted into the opening from
the front and the U-clamp will be installed from the back. Tighten the two nuts on the U-clamp so that the gauge is
secure. Gauge depth to the back of the case is 1". Gauge depth including the mounting studs is 1-7/8". Dakota
Digital CUP-3001 also available, see Page 3 for details.
Factory settings:
Sender type:
Lo warning point:
Hi warning point:
The oil pressure gauge will operate and read correctly between the pressure range of 0-400 psi, 0 – 150 psi, 0-
75 psi, or 0-30 psi depending on the sender type.
This gauge has a user adjustable low and high warning level, which can be set to indicate when the pressure is
too low or too high.
Sender choices:
Gauge Setting Max. pressure display resolution
150
150 psi
400
400 psi
75
73 psi
30
29 psi
These senders have a 1/8" NPT fitting. The fitting and sender threads should be cleaned before installation and no
tape or sealant should be used on the threads. The threads are self-sealing. Single terminal senders ground
through the threads or sender body, senders isolated from the frame will require alternate ground. Dual-terminal
senders have an isolated ground with terminals for both signal and ground.
Contact Dakota Digital if you need to special order a metric thread sender.
The sender must be a Dakota Digital part SEN-1031, SEN1032, or non-polished versions; SEN-03-1, 03-3, 03-
5, 10-1, or 10-2 . Sending units from other manufacturers will cause incorrect readings. If a sender is not
connected properly, the display will show "EEE". If the SND terminal is shorted to ground, the display will show "---".
HLY-3191 ROUND AIR PRESSURE, REV. A
Connect to a main ground location.
Connect to switched 12 VDC power. (An accessory terminal will work for this.)
Night Dimming: connect to the head light switch.
Connect to the pressure sender.
SEN-1031, 150 psi.
10 psi.
100 psi.
1.0
2.0
0.5
0.2
sender part number
SEN-1031(polished)
SEN-03-5
SEN-1032(polished)
SEN-10-1
MAN# 650100A

Advertisement

loading

Summary of Contents for Dakota Digital HLY-3191

  • Page 1 Contact Dakota Digital if you need to special order a metric thread sender. The sender must be a Dakota Digital part SEN-1031, SEN1032, or non-polished versions; SEN-03-1, 03-3, 03- 5, 10-1, or 10-2 . Sending units from other manufacturers will cause incorrect readings. If a sender is not connected properly, the display will show “EEE”.
  • Page 2 Setting the warning limits, sender setup, and update speed: The SND terminal is used to enter and change the warning settings. You will need a wire connected to the SND terminal that can be momentarily grounded while you watch the gauge. The headlight(s) should be off or the DIM terminal unhooked so that it does not interfere with the setup.
  • Page 3 CUP-3001 The gauge can also be mounted into a Dakota Digital CUP-3001, it will include a mounting block with a long stainless screw. A bracket for your handle-bar size will also be required. Remove two nuts and U-clamp from the gauge.