Positioning Your Barbecue
When determining a suitable location for your
barbecue installation, give thought to concerns such
as exposure to wind, proximity to traffic paths, and
keeping any gas supply lines as short as possible.
Never locate the barbecue in a garage, breezeway, or
shed, under an unprotected overhang, or in any other
enclosed area. The barbecue must not be installed
under overhead combustible construction. Position
the barbecue and structure so there is enough room to
safely evacuate the area in case of a fire.
Clearance From Combustible Materials
Clearance dimensions indicate the minimum allowable
distance from the edge of the barbecue to any
combustible materials.
The cut-out structure, countertops, and adjacent work
areas for the Built-In barbecue installation must be
built from noncombustible materials only.
NOTE: If the cut-out is constructed from
non-combustibles then combustible material could be
closer, according to AS/NZS 5263 and AS/NZS 5601.
NOTE: If you have questions on which materials are
considered noncombustible, contact your local building
materials supplier or fire department.
Clearance From Noncombustible Materials
If your installation is to be adjacent to noncombustible
materials, you must consider these dimensions for
minimum lid clearances.
The cut-out structure, countertops, and adjacent work
areas for the built-in barbecue installation must be
constructed from noncombustible materials only.
NOTE: If the cut-out is constructed from
non-combustibles then combustible material could be
closer, according to AS/NZS 5263 and AS/NZS 5601.
NOTE: If you have questions on which materials are
considered noncombustible, contact your local building
materials supplier or fire department.
WARNING: The structure, countertops, and
m
adjacent work areas for the built-in barbecue
installation must be constructed from
noncombustible materials only.
6

CLEARANCES FROM COMBUSTIBLE MATERIALS

2
1
2
24" (610 mm) from edge of barbecue to any combustible surface
CLEARANCES - INSTALLATION ADJACENT TO A NONCOMBUSTIBLE WALL
3
DIMENSIONS
1
0" (0 mm)
2
3" (76 mm)
3
30" (762 mm)
a
Wall made from noncombustible materials
GENESIS NG Burner Valve Orifice Sizes & Consumption Data
Gas Category
360 Models
1.0 kPa
Main Burners 1.75 mm
Sear Burner 1.64 mm
360 Models
57.5 Mj/h
2
1
Barbecue
2
a
DESCRIPTION
Minimum from edge of built-in to noncombustible wall
Minimum above for lid clearance
Minimum countertop to lid clearance height
BURNER VALVE ORIFICE SIZES
460 Models
Main Burners 1.62 mm
Sear Burner 1.62 mm
TOTAL CONSUMPTION DATA
460 Models
63.5 Mj/h