This 'original instructions' document assumes that the operator carrying out any operation with this
product is trained and competent to do so. This manual does not attempt to cover all details or variations
in the equipment. Nor does this manual claim to provide for every possible contingency met in connection
with the installation, operation, or maintenance thereof. Should further information be desired, or should
a particular problem arise which is not covered in sufficient detail, the matter should be referred to
Hi-Force.
OPERATING INSTRUCTION MANUAL
Hi-Force HPP series Petrol Driven Hydraulic Pumps are designed to operate high pressure hydraulic
cylinders and tools with a maximum working pressure of 700Bar. This manual applies to the Hi-Force HPP
series, Petrol Driven Hydraulic Pumps. It contains the latest product information available at the time of
publication and approval. Hi-Force reserves the right to make changes to this document at any time without
notice.
HPP SERIES | PETROL DRIVEN PUMPS
Operating Instruction Manual:
OM-HPP-01
1
From Serial Number:
ALL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hi-Force HPP Series

  • Page 1 Hi-Force HPP series Petrol Driven Hydraulic Pumps are designed to operate high pressure hydraulic cylinders and tools with a maximum working pressure of 700Bar. This manual applies to the Hi-Force HPP series, Petrol Driven Hydraulic Pumps. It contains the latest product information available at the time of publication and approval.
  • Page 2: Table Of Contents

    Operating Instruction Manual: From Serial Number: OM-HPP-01 Table of Contents 1.0 Inspection upon Receipt ..................3 2.0 Safety Precautions ....................3 2.1 Introduction ......................3 2.2 Work Area Safety ....................3 2.3 General Hydraulic System Safety Precautions ..........3 2.4 Hydraulic Pump Specific Safety Precautions ........... 5 3.0 Declaration of Incorporation / Conformity ............
  • Page 3: Inspection Upon Receipt

    If in doubt on the correct use of any Hi-Force equipment, contact your nearest Hi-Force office or distributor. Only qualified personnel should be allowed to operate hydraulic equipment. If an operator has not been trained on high-pressure hydraulic equipment and its safe usage, consult your local Hi-Force sales office or distributor who can offer training courses for operators.
  • Page 4 • Immediately replace any worn or damaged parts using genuine Hi-Force parts only. • DO NOT remove any labels from the product. Replace any damaged or unreadable label immediately.
  • Page 5: Hydraulic Pump Specific Safety Precautions

    3.0 Declaration of Incorporation / Conformity Hi-Force declares that this product has been tested and complies with the standards set out in the relevant EU directives. The EU Declaration of Incorporation / Conformity is included as Annex A to this instruction...
  • Page 6: Component Identification

    Operating Instruction Manual: From Serial Number: OM-HPP-01 4.0 Component Identification Hydraulic Oil Drain Plug Oil Filler Breather Cap Hydraulic Oil Level Gauge Engine Hydraulic Service Connections * Petrol Filler Cap Directional Control Valve ** Engine Oil Filler Cap Protective Roll Frame Throttle Adjustable Pressure Relief Valve Start Pull Cord...
  • Page 7 Operating Instruction Manual: From Serial Number: OM-HPP-01 Figure 4.2: Component Identification...
  • Page 8: Installation/Setup

    Operating Instruction Manual: From Serial Number: OM-HPP-01 5.0 Installation/Setup 5.1 Before First Use 1. Immediately after unpacking, examine the pump for signs of transit damage and if found contact the shipping company. 2. Remove the temporary transit fitting / plate which is fitted in the position of the oil filler breather cap (8) and fit the oil filler breather cap which is packed separately.
  • Page 9: Start Up And Stopping Of Pump

    Operating Instruction Manual: From Serial Number: OM-HPP-01 5.2 Start up and stopping of pump 1. Ensure the lever of the hydraulic directional control valve (4) is in the neutral position. This is fully anticlockwise for models with 2-way valves, and the central position for models with 3- or 4-way valves.
  • Page 10: Hydraulic Connections

    NOTE: When longer hoses are used (especially in the case of smaller capacity Figure 5.2 cylinders), the above procedure may not remove all the air from the system. In these cases, contact your Hi-Force representative for advice on pre-filling hoses with hydraulic oil.
  • Page 11: Operation

    OM-HPP-01 6.0 Operation Hi-Force will not always be aware of what equipment this pump will be used to power. It is the responsibility of the owner and all operators to read, understand and comply with all appropriate safety warnings and operating instructions relating to the equipment being used.
  • Page 12: Pumps With Manual Valves

    Operating Instruction Manual: From Serial Number: OM-HPP-01 6.2 Pumps with Manual Valves 1. Set the adjustable pressure relief valve (6) if required. See section 6.1 for details. 2. With all hydraulic connections made start the pump. Refer to section 5.2 3.
  • Page 13: Maintenance And Storage

    Change the oil every 500 working hours using high quality ISO46 hydraulic oil. • Zero the pump pressure before storing. • Have the pump serviced regularly by a Hi-Force authorised repair centre. 8.0 Specifications HPP │ PETROL DRIVEN PUMPS – GENERAL DUTY, HIGH FLOW Maximum Flow Rate (litres/minute)
  • Page 14: System Components / Accessories

    Operating Instruction Manual: From Serial Number: OM-HPP-01 9.0 System Components / Accessories (Refer to the Hi-force website or latest Hi-Force catalogue, Section: System Components for further details) • High Pressure Hydraulic Hoses • Manifolds and Manifold Assemblies. • Flow Control Valve •...
  • Page 15: Troubleshooting

    Operating Instruction Manual: From Serial Number: OM-HPP-01 10.0 Troubleshooting Hi-Force HPP petrol driven hydraulic pumps should be serviced and repaired only by authorised Hi-Force repair centres. The following table gives possible causes and solutions for common problems. TROUBLESHOOTING GUIDE Problem...
  • Page 16 Operating Instruction Manual: From Serial Number: OM-HPP-01 Head Office: Hi-Force Limited Prospect Way, Daventry Northamptonshire NN11 8PL United Kingdom Tel: + 44 1327 301000 | Fax: + 44 1327 706555 www.hi-force.com Regional Offices: For information on our offices worldwide, scan the below QR code...

Table of Contents