TYPICAL INSTALLATION / DIAGRAM OF KEY
COMPONENTS
TYPICAL ADD-ON COOLING COIL
Indoor Unit
18°C - 30°C
Indoor and Outdoor unit operating temperature range:
TYPICAL OUTDOOR UNIT
Outdoor Unit
-15°C - 48°C
INDOOR COOLING COIL UNIT DIMENSIONS
CONSIDERATIONS WHEN CHOOSING A LOCATION:
Select a location by choosing a place:
• That is easy for refrigeration piping and condensate drainage
• That can carry the added weight of the appliance
• Which has easy access for maintenance
• Which should not be near any heat source or moisture
• Where water is easily drained out
• Where duct connections can be made with ease
Additionally consider:
• Ensure duct thermistor is placed downstream of indoor coil
• Ensure duct from heater to coil is as straight as possible
• Ensure return air duct is sized accordingly
Dimension (mm)
Supply Air
Model
A
D
SACV10D1S
366
290
SACV12D1S
366
290
SACV14D1S
366
290
SACV16D1S
412
290
SEELEY INTERNATIONAL - INSTALLATION MANUAL |
Return Air
B
E
F
G
946
290
946
450
1280
946
290
946
450
1280
946
290
946
450
1280
1110
290
1110
435
1442
C
7