Specification And Patametet - Ebyte E07-900M10S Manual

Cc1101 855-925mhz 10dbm spi wireless module
Hide thumbs Also See for E07-900M10S:
Table of Contents

Advertisement

9
Chengdu
Ebyte Electronic Technology Co. Ltd
E07-900M10S
User Manual
®
Health care products;
®
Advanced Meter Reading Architecture(AMI),
®
Automotive industry applications.
2
Specification and Parameter
2.1 Limit Parameter
Performance
Main parameter
Remark
Min
Max
Voltage over 3.6V will cause permanent damage to
Power supply (V)
0
3.6
module
)
Chances of burn is slim when modules are used in
Blocking power (dBm>
-
10
}
short distance
Operating temperature
(°C)
-40
+85
Industral grade
2.2 Operating Parameter
Performance
Main parameter
Remark
Min
Typical
Max
Operating voltage
(V)
18
33
3.6
3.3 V ensures output power
Communication level
(V)
-
33
-
For 5V TTL, it may be at risk of burning down
Operating temperature
(°C)
-40
-
+85
Industral grade
Operating frequency
(MHz)
855
868
925
Support ISM band
Power
TX current
(mA)
-
36
-
Instant power consumption
Consump- | RX current (mA)
-
18
-
-
tion
Sleep current
(pA>
-
0.6
-
Shut down by software
Max TX power (dBm)
9.5
10
11
-
Receiving sensitivity
(dBm)
-105
-107
-108
Air data rate 1s 1.2kbps
Air datarate
(bps)
0.6k
-
500k
Controlled via user's programming
Main parameter
Description
Remark
Test condition:
clear and open area, antenna gain: 5dB1,
Reference distance
1.5km
)
)
antenna height: 2.5m,
air data rate: 1.2kbps
FIFO
64Byte
Maximum length of a single transmission
Crystal Oscillator
26MHz
10ppm
Modulation
GFSK(recommended)
| Support OOK.
ASK.
GFSK.
2-FSK.
4-FSK and MSK
Copyright ©2012-2021,
Chengdu Ebyte Electronic Technology Co.Ltd.

Advertisement

Table of Contents
loading