Specification And Parameter; Limit Parameter; Operating Parameter - Ebyte E22-400M30S User Manual

Sx1268 433/470mhz spi smd lora module
Hide thumbs Also See for E22-400M30S:
Table of Contents

Advertisement

ene
Chengdu Ebyte Electronic Technology Co, Ltd.
E22-400M30S User manual
1.3 Application
Home security alarm and remote keyless entry ;
Smart home and industrial sensors |
Wireless alarm security system ;
Building automation solutions ;
Wireless industrial-grade remote control ;
Health care products ;
Advanced Meter Reading Architecture(AMI) ;
Automotive industry applications.
2. Specification and parameter
2.1 Limit parameter
Performance
Main parameter
Remark
Min.
Max.
Voltage over 5.5V will cause permanent
Power supply (V)
0
5.5
damage to module
Chances of burn is slim when modules
Blocking power (dBm>
-
10
}
}
are used in short distance
Operating temperature
(°C)
-40
85
2.2 Operating parameter
.
Performance
Main parameter
Remark
Min.
Typ.
Max.
Operating voltage
(V)
2.5
5.0
5.5
It's recommended to use 5V.
For 5V TTL, It is recommended to add level
Communication level (V)
33
]
conversion.
Operating temperature
(°C)
-40
-
85
Industrial design
Operating frequency
(GHz)
410
433/470/490
493
Support ISM band
TX current (mA)
650
Instant power consumption
Power
}
RX current (mA>
14
consumption
Sleep current
(pA)
3
Software 1s shut down
Max Tx power
(dBm)
214
215
223
Receiving sensitivity
(dBm)
-149
-150
-151
Air data rate is 0.3kbps
0.6k
-
300k
Controlled via user's programming
Air data rate (bps)
0.018k
62.5k
Controlled via user's programming