Specifications - Mitsubishi Electric PCA-M KA Series Operation Manual

Hide thumbs Also See for PCA-M KA Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
6. Trouble Shooting
Draining water or motor rotation sound is heard.
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display
is faint, or signals are not received by the indoor unit unless the remote
en
controller is close.
After battery installation/replacement of remote controller, part of function
cannot be used.
The operation lamp near the receiver for the wireless remote controller
on the indoor unit is blinking.
The indoor unit which is not operating becomes warm and a sound, simi-
lar to water flowing, is heard from the unit.

7. Specifications

PCA-M·KA Series
Model
Power source (Voltage/Frequency)
Rated Input (Indoor only)
Rated Current (Indoor only)
Heater
Dimension (Height)
Dimension (Width)
Dimension (Depth)
Fan airflow rate (Low-Middle2-Middle1-High)
Noise level (Low -Middle2-Middle1-High)
Net weight
Model
Cooling Capacity
Heating Capacity
Total electric power input
Sound power level
(per speed setting, if applicable)
(EU)2016/2281
12
Having trouble?
<V/Hz>
<kW>
0.04/0.04
<A>
0.29/0.27
<kW>
<mm>
<mm>
<mm>
10-11-12-14 10-11-13-15 15-16-17-19 16-17-18-20 22-24-26-28 23-25-27-29 24-26-29-32
<m
/min>
3
<dB> 31-33-36-39 32-34-37-40 33-35-37-40 35-37-39-41 37-39-41-43 39-41-43-45 41-43-45-48
<kg>
sensible
P
<kW>
rated,c
latent
P
<kW>
rated,c
P
<kW>
rated,h
P
<kW>
0.040
elec
L
<dB>
WA
Here is the solution. (Unit is operating normally.)
When cooling operation stops, the drain pump operates and then
stops.
Wait approximately 3 minutes.
The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
the noise specification, which was measured in anechoic room.
Location
examples
Noise levels
The batteries are low.
Replace the batteries and press the Reset button.
If nothing appears even after the batteries are replaced, make sure
that the batteries are installed in the correct directions (+, –).
Please check that the clock setting is completed. If clock setting is not
done, please complete.
The self diagnosis function has operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
A small amount of refrigerant continues to flow into the indoor unit
even though it is not operating. (Connected with MXZ/Branch box)
M35
M50
M60
0.05/0.05
0.06/0.06
0.37/0.37
0.39/0.39
-
-
-
960
25
26
M35
M50
M60
3.08
3.95
4.86
0.42
1.05
1.14
4.00
5.70
6.90
0.050
52-54-57-60
53-55-57-60 56-58-60-62 57-59-61-63 59-61-63-65 61-63-65-68
High sound
Normal rooms
absorbing rooms
Broadcasting
Reception room,
studio, music
hotel lobby, etc.
room, etc.
3 - 7 dB
6 - 10 dB
M71
M100
~/N 230/50, 230/60
0.06/0.06
0.09/0.09
0.42/0.42
0.65/0.65
-
-
230
1280
680
32
37
M71
M100
5.39
7.70
1.71
2.30
8.10
11.20
0.060
0.090
Low sound
absorbing rooms
Office, hotel
room
9 - 13 dB
M125
M140
0.11/0.11
0.14/0.14
0.76/0.76
0.90/0.90
-
-
1600
38
40
M125
M140
9.00
9.64
3.50
3.76
14.00
16.00
0.110
0.140

Advertisement

Table of Contents
loading

Table of Contents