Thermador Professional PH Series Installation Instructions Manual page 7

Wall hoods
Hide thumbs Also See for Professional PH Series:
Table of Contents

Advertisement

Available languages

Available languages

Drywall
Screws
(2 ea. #14 x 3")
Cooktop
N
Centerline
A measurement
11.
Discharge Direction: Horizontal discharge
requires a wall cutout, as shown in Figure 5, to
provide clearance for the transition. The location
of the cutout is determined by the hood
installation height.
10-14"
Transition
Centerline
annie
(
10-1/2"
Figure 6
The transition supplied with the hood connects to
standard 10-inch round duct. Figure 6 shows the
transition connected for horizontal discharge.
HOOD SIZE
30"
13-the"
36"
16-16"
42"
19-1he"
43"
22-1116"
54"
25-16"
Figure 4
Dry Wall
23"
Cooktop
\
Centerline
Base of Hood
Location
Wall
Transition Centerline
10-1/4"
48"
Figure 5
Note: Dashed line indicates cutout needed for
clearance of the transition.
Figure 7
Figure 7 shows the hood configured for vertical
discharge. Installations using this type of method
require a cutout in the ceiling to accomodate 10"
duct and the 1/2" conduit carrying power to the unit.
Duct covers, sold separately, are available to cover
the space between the top of the hood and ceiling.
(See Page 3).