Siemens SIMATIC NET RUGGEDCOM RS920W Equipment Manual page 33

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS920W:
Table of Contents

Advertisement

Communication Ports
4.2 EoVDSL Ports
Universal and Long-Reach EoVDSL ports (master or slave) must be connected to
EoVDSL ports (slave or master) of the same type. Connection between Universal
EoVDSL ports and Long-Reach EoVDSL ports is not supported. While master/slave
mode can be modified on Universal EoVDSL ports, the operating mode of all Long-
Reach EoVDSL ports is predetermined by hardware. As a result, master/slave mode
cannot be modified on Long-Reach EoVDSL ports.
LEDs
Each EoVDSL port has a Link/Act LED and a Master LED. On devices with Universal
EoVDSL ports, the Master LED can be toggled on or off depending on whether the
port is set to be a Master or Slave. On devices with Long-Reach EoVDSL ports, the
Master LED will be on all the time if the device is set to be the Master, or off if the
device is set to be the Slave.
Master
Link/Act
Pin-Out
The following is the pin-out for the RJ11 connectors:
Note
All RJ11 connectors conform to the standard telephony pin configuration.
6
Figure 4.2
24
NOTICE
LED
1
EoVDSL RJ11 Modem Port
State
Green (Solid)
Off
Green (Solid)
Green (Blinking)
Off
 
Description
The device is in Master mode.
The device is in Slave mode.
Link established
Link activity
No link detected
Pin
Description
1
Reserved (Do
Not Connect)
2
Reserved (Do
Not Connect)
3
Ring
4
Tip
5
Reserved (Do
Not Connect)
6
Reserved (Do
Not Connect)
Equipment Manual, 11/2023, C79000-G8976-1033-12