Empresa Instruction Manual
IFU-FL6-001EN Rev 02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMPRESA NSB-0-FL6-000 and is the answer not in the manual?

Questions and answers

HEALTH SYSTEM SERVICES - NORTH CAROLINA
May 2, 2025

why will the bed not raise from the floor position when 1 push button 5?

Subscribe to Our Youtube Channel

Summary of Contents for Accora EMPRESA NSB-0-FL6-000

  • Page 1 Empresa Instruction Manual IFU-FL6-001EN Rev 02...
  • Page 2: Table Of Contents

    Contact Details ------------------------------------ 31 T: +353 (0)1 695 0614 Design Policy and Copyright ® and ™ are trademarks belonging to Accora Ltd unless otherwise stated. As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice. © Accora Ltd...
  • Page 3: Product Overview

    Product Overview Footboard Headboard Headboard (design may vary) Mattress guides 15. Control Box Footboard (design may vary UDI Label 16. Side panel (optional) Mattress platform 10. Manufacturers nameplate inc. 17. Side panel centre bracket Handset serial number 18. Side panel end bracket Central brake lever 11.
  • Page 4: General Warnings

    Never stand on the bed. Do not smoke in or around the bed. Do not lower the bed while a hoist that Accora shall not be held liable for any extends beneath the bed is being used. Hoist access is obtained when...
  • Page 5: Means Of Delivery

    Accora in writing. 11. If a lifting pole or infusion stand is fixed to If the bed needs transporting between the bed, increased attention must be...
  • Page 6: Use Environments

    3. Use Environments -------------------------- 4. Intended Use --------------------------------- This bed is intended for use in the following The Empresa is intended to be used as a application environments: nursing bed in the Use Environments listed. The patient user group for the bed is adult 1.
  • Page 7: Technical Specification

    5. Technical Specification ------------------- Environmental information: Meters Temperature Relative Atmospheric Condition above sea Range Humidity pressure The table below lists the Empresa part level numbers; some models may not be available +5°C to +40°C Operating 20% to 80% +41°F to +104°F 700 hPa to Max.
  • Page 8: Accessories

    6. Accessories ---------------------------------- 7. Electrical Specification ------------------- Duty Cycle: Intermittent operation 2 min/18 Due to differing regulatory requirements, not min. After the maximum continuous action of all the accessories are available in all two minutes, there must be a break of 18 regions.
  • Page 9: Assembly

    8. Assembly -------------------------------------- 2. Remove the packaging and identify all the components: Bed frame WARNING Mattress platform. Assembly MUST be carried out by Handset. Mattress guides (4 off). suitably trained and qualified personnel. Headboard & footboard brackets and fixings. All functions MUST be tested and Headboard &...
  • Page 10 10. Fix the brackets to the footboard using the M8 x 35 bolts, nuts, and washers provided as shown in Figure 8.5. Tighten using the 5mm Allen key and a 13mm spanner. Standard Figure 8.3 4. To move the handset cable to the right side of the bed, remove the handset Extended cable connector from the left side socket.
  • Page 11: Assembly Of Side Panels (Optional)

    14. Align the bolt holes and secure the mounting brackets using the M8 x 20mm bolts and washers provided as shown in Figure 8.7. Tighten using the 5mm Allen key. Figure 8.9 Figure 8.7 17. Carry out the Functionality Check in 15.
  • Page 12 3. The side panel middle bracket is shown 4. Fit the claw to the plate in the correct below in Figure 9.2. The claw may be position for the bed configuration using fitted to the plate in one of four positions, two M6 x 20 bolts and M6 washers.
  • Page 13 6. Fit the assembled middle bracket to the 7. Mount the side panels onto the bed frame side panel. There are two sets of fixing as shown in Figure 9.6. Position the side holes on each side panel, depending panel between the headboard and which side of the bed the side panel is footboard and fit the centre bracket claw fitted, as shown in Figure 9.4.
  • Page 14: Bed Controls And Indicators

    10. Bed Controls and Indicators ------------ The handset is used by the user or caregiver to change the position of the of the backrest and legrest sections and to adjust the height WARNING of the mattress platform of the bed. Always Bed positioning MUST be carried out by check for obstructions before the bed is suitably trained and qualified personnel.
  • Page 15 Safety stop position Backrest – Raise / Lower The safety stop position is the position the bed will stop at when lowering the bed using Legrest – Raise / Lower button 6. The mattress platform height will be approximately 20cm. To use the floor level Mattress Platform –...
  • Page 16: Floor-Level Function

    11. Floor-level Function ----------------------- 1. Check underneath the bed to make sure there are no obstructions or entrapment risks. WARNING 2. When lowering the bed, make sure the user or patient keeps hands and legs away from the edge of the mattress. Extreme care must be taken when using the floor-level function.
  • Page 17: Length Adjustment

    12. Length Adjustment ------------------------ Standard The Empresa can be extended by 9cm at the head end and 9cm at the foot end. Refer to Extended section 15 for the appropriate length setting for the mattress being used. To extend the bed: 1.
  • Page 18: Functionality Check

    13. Functionality Check------------------------ 14. Using the Castor Brakes ----------------- There are two types of castors fitted to the WARNING Empresa, depending on model. Care must be taken to make sure the castor Functionality check MUST be carried out brakes are always locked when the bed is in by suitably trained and qualified use, being assembled or dismantled, so that personnel.
  • Page 19: Mattress Selection

    220mm or greater. Bed extension MUST be carried out by suitably trained and qualified personnel. Please contact Accora for Figure 14.3 compatible mattresses. Incompatible mattresses 2. To unlock the brake, press firmly...
  • Page 20: Siderail Selection

    WARNING Moving or repositioning MUST be carried Only use side rails that are compatible out by suitably trained and qualified with this bed as supplied by Accora. personnel. Incompatible siderails can create hazards All functions MUST be tested and and entrapment risks.
  • Page 21: Cable Routing For Mattress Pump

    18. Cable Routing for Mattress Pump --- Head End WARNING When fitting accessories with a power cable to the Empresa, the bed must be disconnected from the mains power supply. Careful consideration needs to be given to Figure 18.2 the cable route to ensure that their function is not compromised by crushing Foot End or shearing from the bed mechanism.
  • Page 22: Cleaning & Disinfection

    The bed is not designed for maintenance in automatic bed washers or for cleaning with pressurised water, spraying, showering or steam cleaning. Accora cannot be liable for any damage or risk of damage if inappropriate cleaning or disinfectant agents are used.
  • Page 23: Troubleshooting

    If the bed still does not function correctly, platform at the control box as shown in contact Accora for further advice. Figure 20.1 Headboard Indicator light...
  • Page 24: Storage

    21. Storage ----------------------------------------- 22. Daily Inspection ----------------------------- For problem-free storage we recommend: Daily visual inspection is strongly recommended and may be carried out by caregiver, user or other person. 1. Disconnect the bed from the electrical supply. The following checks must be carried out: 2.
  • Page 25: General Maintenance

    23. General Maintenance ---------------------- 24. Guarantee ------------------------------------- The Empresa has a warranty period of 2 WARNING years on the electrical components and accessories, and 10 years on the frame. Maintenance MUST be carried out by suitably trained and qualified personnel. All functions MUST be tested and approved after maintenance by suitably 25.
  • Page 26: Emc Statement

    26. EMC Statement --------------------------------------------------------------------------------------------------- Guidance and manufacturer’s declaration-electromagnetic emissions The bed is intended for use in the electromagnetic environment specified below. The customer or the user of the bed should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance RF emissions...
  • Page 27 Guidance and manufacturer’s declaration-electromagnetic immunity The bed is intended for use in the electromagnetic environment specified below. The customer or the user of the bed should assure that it is used in such an environment. IEC 60601 Compliance level Electromagnetic Immunity test test level environment-guidance...
  • Page 28 Guidance and manufacturer’s declaration-electromagnetic immunity The bed is intended for use in the electromagnetic environment specified below. The customer or the user of the bed should assure that is used in such and environment. Compliance Immunity test IEC 60601 test level Electromagnetic environment-guidance level Conducted RF...
  • Page 29 Recommended separation distance between portable and mobile RF communications equipment and the bed. The bed is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the bed can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the bed as recommended below, according to the maximum output power of the communications equipment.
  • Page 30: Table Of Symbols

    27. Table of Symbols ------------------------------------------------------------------------------------------------ General warning General caution Complies with the European Medical Device Regulation 2017/745 Model number Serial number Maximum patient weight Physical description of an adult Manufactured date Manufacturer Medical Device in accordance with EU Medical Device Regulation 2017/745 Floor-Level function warning Ensure the side rails are compatible with the bed before...
  • Page 31: Contact Details

    Degree of protection against electric shock: Class II Double Insulated For indoor use only IPX6 Degree of protection against liquid ingress EC Representative 28. Contact Details ---------------------------------------------------------------------------------------------------- UK and Rest of World Accora Ltd. Charter House Accora Inc. Barrington Road 9210 Corporate Blvd. Suite 120 Address Orwell Rockville...
  • Page 32 Accora Barrington Road Orwell Cambridge SG8 5QP United Kingdom T: +44 (0)1223 206100 info@accora.care www.accora.care...

This manual is also suitable for:

Empresa nsb-1-fl6-000Empresa nsb-2-fl6-000