When the refrigerator is not in use
In case the appliance will not be used for a long time
follow these steps:
Break the circuit of the appliance.
Remove foods from the refrigerator.
Defrost and clean it as written before.
Leave the door open to avoid a build up of air inside.
Double shooting
How to change the bulb
Should the light fail to work you can change it as
below:
Break the circuit of the appliance.
Unscrew the plate screw fixing the lamp cover, then
take the lamp cover off in the direction of arrow and
the bulb can be changed. (Type of the bulb: Mignon
322, 230 V, 15 W, E 14 thread)
After changing bulb replace the lamp cover, screw the
plate screw and apply voltage to the appliance.
The lack of light does not influence operation of the
refrigerator.
If something does not work
During operation of the appliance some smaller but
annoying trouble can often occur, which does not
require calling a technician out. In the following chart
information is given about them to avoid unnecessary
charges on service.
We draw your attention that operation of appliance goes
with certain sounds (compressor- and circulating
sound). This is not trouble, but means normal
operation.
* We draw it to your attention again that the
L'-J appliance operates discontinuously, so the
stopping of compressor does not mean being no-
current. That is why you must not touch the electrical
parts of the appliance before breaking the circuit.
Inasmuch as the advice does not lead to result, call the nearest brand-mark service.
62
l.
4/ RAMprid!
Problem
Possible cause
Solution
The appliance does not
Thermostatic control is set too low.
Set higher position.
cool sufficiently
Too many foods to be cooled were put in.
Put fewer foods to be cooled.
Very warm foods were put in.
Put foods max. at room temperature.
Door is not shut properly.
Check if the door is shut.
There is no inside cool air circulation.
Provide inside cool air circulation.
The appliance cools too
The thermostatic control is set too high.
Set lower position.
hard
The appliance does not
Plug is not connected to the mains socket
Check if the connection is proper.
cool at all
properly.
There is no voltage in the mains socket.
Check if there is voltage.
Thermostatic control is in „0" position.
Check setting of thermostatic control.
The appliance is noisy
The appliance is not supported properly
Check if the appliance stands stable (all the four
feet should be on the floor):