Firmware Upgrades

Panel Requirements
MPA2C3 panels must first be upgraded to the latest release firmware version Refer
to the release notes for more information.
Note: The secondary (downstream) EVL panels should be upgraded first and then the
primary (Primary) panel(s).
Note: For detailed upgrade instructions, refer to th MPA2C3 User Manual.

4-door License

A 4-door license is required for 3-door or 4-door access control unit. To obtain 4-
door access control system, you need to buy the specific license. Once the license
file is applied on the panel then user can use the 4-door controller. Please contact
Honeywell Customer Support team for 4-door license.

Basic Standalone Operation

Card Read / Door Lock Operation
1. Present a card to a reader.
2. The reader sends the card number to a reader input on the panel.
3. The panel searches its database and:

Door Egress (REX) / Door Lock / Door Status Operation

1. Activate the door egress input (REX).
2. The panel activates the door relay associated with the particular door egress
If the door status goes from close to open to close again during the 10 second door
open period, the door relay will be immediately de-activated.
168
If it is a valid card, activate the door relay associated with the particular reader
input. The card is valid when it is in the card database on the panel and the
current time and date conforms to the time zone associated with the card.
If it is not a valid card, the door relay remains locked.
input for a default pulse time of 10 seconds.