ADJUSTMENT
Measuring Equipment for Adjustment
1. Digital voltmeter (D.V.M)
input impedance: High
2. RF valve voltmeter (RF V.M)
Input impedance: 1M
or more, 2 pF or less
Voltage range: Full scale = 10mV to 300V
Measurable frequency range: up to 450MHz
3. Frequency counter (f. counter)
Input sensitivity: About 50mV
Measurable frequency: 450MHz or more
4. DC power suppiy
Voltage: Variable in the range 10 to 17V
Current: 13A or more
5. Power meter
Measurement power: 60W, 30W, 10W
Impedance: 50
Measurable frequency: 450MHz
6. AF valve voltmeter (AF V.M)
Input impedance: 1MQ or more
Voltage range: Fuil scale = 1mV to 30 V
Measurable frequency range: 50Hz to 10kHz
7. AF generator (AG)
Output frequency: 100Hz to 10kHz
Output voltage: 0.5mV to 1V
8. Line detector
Measurable frequency: 450MHz
9. Spectrum analyzer
Measurable frequency: 450MHz
10. Directional coupler
11. Oscilloscope
High sensitivity with horizontal input terminal
12, Standard signal generator (SSG)
The standard signal generator must be able to generate
the 1GHz band frequencies and vary the amplitude and
frequency.
Output: -133dBm to greater than -13dBm
13. Dummy load (for AF)
8Q, about 5W
14.Noise generator
The noise generator must be able to generate noise
similar
to
ignition
noise
containing
high-frequency
components of 450MHz or more.
15.Sweep generator
The sweep generator must be able to sweep the 144
and 430MHz bands.
16. Tracking generator
17. Adjustment jig
Preparation
@
Set the controls and switches to the positions listed
below unless otherwise specified.
VOL control
Fully counterclockwise
SQL control
Fully counterclockwise
POWER switch
OFF
(For fixed stations)
OFF
DC power supply POWER switch
uP ——
——
DWN
C8
(DC8V:100mA max.)
NC
E
MC
PTT
ME
Microphone socket
(as viewed from the front of the set)
Use
an
insulated
rod, such
as a plastic rod, for
adjustment (especially for trimmers, coils, etc.).
To protect the signal generator, never connect the
microphone
to the microphone
socket
when
the
receiver section is adjusted.
@
Before the power cord is connected, make sure the
power switch is off.
Without specification of SSG, standard modulation is
applied (MOD : 1kHz, DEV : +3kHz, AF output : _
0.63V/8Q)
@
See the instruction manual for transmit and receive
operations.