Panasonic Lumix S-R24105 Service Training Manual page 18

Interchangeable lens for digital camera
Table of Contents

Advertisement

6.2.2.3. Installation of the 1st Lens Frame Unit
1st Lens
Frame Unit
1st Lens
Frame Unit
1st Cam Pin
Screw(H)
3. Tighten screw (H) by using the torque driver with specified torque.
4. Glue the 1st Cam Pin with "Three Bond 1401B or 1401C"
<Caution>
- The glue does not come out above the 1st Lens Frame Unit
- Make sure the Glue has hardened before proceeding installation
1. Install 1st Cam Pin to Cam Barrel Unit
with adjusting the rotational phase
as the 2-5 Cam Pin penetrates.
2.
Install 1st Lens Frame Unit to Cam Barrel Unit
with adjusting the rotational phase
as shown
The position of ▲ depends on
the position of the cam frame.
At Wide end, ▲ will be at here.
Front
side
<Note>
- At this illustration,
Rear
(body)
side
- Screw(G) × 3
- Torque : 15±1Ncm
* Standard time for curing : 3 to 5 hours
▲ marking
in the figure.
the lens of front side is upward.
But it is easier to work with the rear side up.
BLACK
4
4
5.8mm