6.1.2.6. Removal of Ring Mount Base Unit
Screw(F)
Zoom Drive Pin
Encoder brush
Screw(G)
Remove 2 FPCs from convex
1. Remove the Screw(F)
2. Remove Zoom Drive Pin
3. Remove 4 Screws (G)
4. Remove Ring Mount Base Unit
<Caution>
- Care about Encoder brush (red circle).
(Tips) rotate the ring toward TELE side a little
to prevent it from coming off.
SILVER
7mm