Appendix D: SafeDC™

When AC supply to the inverter is shut off (by shutting off the AC breaker at the site), or when the 
inverter ON/OFF switch is turned to OFF, the DC voltage drops to a safe voltage of   p er optimizer.
The SolarEdge inverters are certified for compliance with the following standards as disconnection 
devices for PV generators, meaning that they can replace a DC disconnect:
 
IEC 60947-3:1999 + Corrigendum: 1999 + A1:2001 + Corrigendum 1:2001 + A2:2005;
l
 
DIN EN 60947-3
l
 
VDE 0660-107:2006-03
l
 
IEC 60364-7-712:2002-05
l
 
DIN VDE 0100-712:2006-06.
l
In compliance with these standards, the disconnection mechanism operates as follows:
 1.  Turn the inverter ON/OFF switch, located at the bottom of the inverter, to OFF, or disconnect the AC 
by shutting off the AC breaker at the site. The DC voltage displayed on the inverter LCD begins to 
decrease.
If the AC breaker was shut off, the LCD does not display. In this case, wait five minutes.
 2.  When the DC voltage reaches a safe voltage, the PV connectors at the input to the inverter can be 
disconnected. A galvanic separation then exists between the PV array and the inverter.