Chapter 6: Setting Up Communication; Communication Options; Ethernet; Rs485 - SolarEdge SE8000H-AU Installation Manual

Single phase inverter with hd-wave technology
Table of Contents

Advertisement

Chapter 6: Setting Up Communication

Chapter 6: Setting Up Communication
The inverter sends the following information to the monitoring platform:
 
Power optimizer information received via the DC power lines (the PV output circuit)
l
 
Inverter information 
l
 
Information of any other connected devices
l
 
This chapter describes setting up communication between: 
 
the inverter and the monitoring platform through the Internet (wired/ wireless), or through a cellular 
l
connection
 
multiple inverters   f or a master/slave configuration
l
Communication setup is not required for power harvesting, however it is needed for using the 
monitoring platform.
CAUTION!
 
When connecting the communication cables, make sure that the ON/OFF switch at the bottom of the
inverter (and the switch of the DC Safety Unit if applicable) is turned OFF, and the AC is turned OFF.
When configuring the communication parameters, make sure that the ON/OFF switch (and the switch
of the DC Safety Unit if applicable) is OFF, and the AC is turned ON.

Communication Options

The following types of communication can be used to transfer the monitored information from the 
inverter to the   m onitoring platform.
Only communication products offered by SolarEdge are supported.

Ethernet

Ethernet is used for a LAN connection. For connection instructions refer to Creating an Ethernet (LAN) 
Connection on page 47. 

RS485

RS485 is   u sed for the connection of multiple SolarEdge devices on the same bus in a master-slave 
configuration. RS485 can also be used as an interface to external   d evices, such as meters and third party 
data loggers.
 
RS485-1: Enables the connection of multiple devices (inverters/Commercial Gateway) over the 
l
same bus, such that connecting only one device to the Internet is sufficient to provide 
communication services for all the devices on the bus.
 
RS485 Plug-in: The RS485 Plug-in provides an additional RS485 port for the 
l
inverter for enhanced communications. The kit contains a module, which is 
installed on the communication board, and has a 3-pin RS485 terminal block. 
This kit is provided with an installation guide, which should be reviewed prior to 
connection see,  
expansion_kit_installation_guide.pdf 
For connection instructions refer to Creating an RS485 Bus Connection on page 50.
44
Single Phase Inverter with HD-Wave Technology Installation MAN-01-250-1.2
h ttps://www.solaredge.com/sites/default/files/RS485_

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se3000h-auSe2500h-au

Table of Contents