MAINTENANCE
l Turn the lock knob to the unlocked position.
l Remove the engine service cover.
l Remove the screw and air filter cover.
l Remove the air filter from the air cleaner housing and
place it in a suitable cleaning container. Replace the air
filterifdamaged.
NOTE: The air filter may be covered in oil. Use an appro-
priate container.
l Wash the air filter by submerging the filter in a solution
of household detergent and warm water. Slowly squeeze
the filter to thoroughly clean.
NOTICE
DO NOT twist or tear the air filter during
cleaning or drying. Only apply slow but firm squeezing
action.
l Rinse the air filter by submerging it in fresh water and
applying a slow squeezing action. Allow the filter to dry
thoroughly.
NOTICE
Do not pollute. Follow the guidelines
of the EPA or other governmental agencies for proper
disposal of hazardous materials. Consult local author-
ities or reclamation facility.
l Dip the air filter in clean engine oil then squeeze out all
excess oil. The engine will smoke when started if too
much oil is left in the filter.
l Install the air filter in the air cleaner housing and reinstall
the air filter cover.
l Install the engine service cover and turn the lock knob to
the locked position to secure.
CHANGING THE ENGINE OIL
See Figure 15.
For optimal performance, change the engine oil according
to the figures specified in the maintenance schedule or
the engine manual (if applicable). When using the generator
under extreme, dirty, dusty conditions or in extremely hot
weather, change the oil more frequently.
NOTE: Change the oil while the engine is warm but not
hot. Warm engine oil drains more quickly and thoroughly
than cool lubricant. Contact with hot lubricant will cause
serious burns.
FIG. 15
A - Oil dipstick
l Turn the generator off and allow the engine to cool for
30 minutes.
l Place the generator on a level surface in a well-ventilated
area.
l Turn the lock knob to the unlocked position.
l Remove the engine service cover.
l Clean the area around the oil dipstick.
l Slowly unscrew and remove the oil dipstick.
l Place an oil pan (or suitable container) under the oil fill/
drain hole.
l Tilt the generator to drain the oil.
l After the oil has drained completely, place the generator
in an upright position.
l Refill the oil as described in the Operations section.
l Replace the oil dipstick and hand-tighten.
l Clean up any spilled oil.
l Install the engine service cover and turn the lock knob to
the locked position to secure.