If you are using the Interconnect feature, the detectors will beep and flash 2× a second.
If the detector does not emit an acoustic signal, check the battery and the correctness of assembly.
Use test mode 1× a week to make sure the detector is functional.
Note: The acoustic and optical alarm during testing is only used as indication that the detector is
operational. It does not mean that the presence of smoke has been detected.

FAULT STATE

If the detector is in fault state, it is not functional.
Fault state is indicated every 40 s by 1× beep with the green LED constantly lit.
Immediately replace the battery and check that the detector is undamaged; clean the openings of
the detector by e.g. a vacuum cleaner. Do a function test.
If the fault state persists even after the battery has been replaced, contact a service centre.

LOW BATTERY

A low battery in the detector is indicated by a single simultaneous beep and flash of the red LED
every 40 s at least 30 days before the battery runs out. Immediately replace the battery. Use
alkaline batteries only; do not use rechargeable batteries.
Do a function test.
It is recommended to replace the battery 1× a year as a precaution.
END OF LIFE OF THE DETECTOR
The detector has a service life of 10 years since production.
After expiration, the detector must no longer be used and must be replaced with a new device.
The replacement date for the detector is listed on the label on the back, next to „Replace device".
If you are using multiple detectors, remember to check their replacement dates!

ALARM WARNING

If smoke is detected, the detector will start emitting an acoustic + optical signal.
The detector will start beeping continuously 1× a second, with the red LED flashing and the green
LED constantly lit up.
If you are using the Interconnect feature, the detectors will beep and flash 2× a second.
The alarm will be active until the air clears.
The acoustic signal of the alarm can be temporarily silenced by pressing the TEST button.
The acoustic signal will be silenced for 8 minutes; the red LED will continue flashing.
When using the Interconnect feature, each detector has to be silenced individually.
After 8 minutes, the acoustic signal will reactivate until the air clears.
If an alarm triggers, immediately evacuate the building and make sure all other people have left as well.
Do not stop to call help or pick up your belongings.
Contact the corresponding emergency service.
Wait until the air clears.
Do not remove or disconnect the battery to silence the alarm – that deactivates the detector!
Overview of Possible Fault States of the Detector
State
Test mode not functioning.
Alarm indication by a simultaneous 1× beep/
1× flash of the red LED.
The alarm beeps every 40 seconds (the
detector is in fault mode).
The device triggers random alarms during
cooking of showering.
Solution
1. Check that the battery is connected correctly.
2. If the fault reappears, return the device.
1. The battery is low, replace it.
1. Clean the detector.
2. Return the device or replace it with a new one.
1. Silence the alarm using the TEST button.
2. Clean the detector.
3. Move the detector to a more suitable location
and do a function test using the TEST button.