FAULT
A
The power ON light does not
come on when the switch is
pressed.
B
The melter and top surface of
the appliance remain cold to the
touch.
C
The melter fails to reach the
required temperature.
D
The temperature measured by
the device is not correct

7.0 TROUBLESHOOTING

POSSIBLE CAUSE
No power to 230V
socket
Electrical system protection
has tripped (thermal-magnetic
circuit breaker, circuit breaker,
residual current device).
Programming board
No mains power
Operating temperature set too
low
Break in heating element.
Break in power cable.
Intermittent contact in
socket / plug connection.
Intermittent contact inside the
appliance.
the probe is not well-immersed
in the chocolate
DPLMCD - ENGLISH
REMEDY
power
1. Unplug the power cable.
AC
2. Check that the fault is not
attributable to the melter.
3. If it is a fault with the
electrical system, call in a
professional electrician to make
the necessary repairs.
4. Plug the appliance back in
and turn it back on.
5. If it is the melter that has
caused the electrical system
protection to trip, contact the
dealer or manufacturer to
arrange for replacement or
repair as necessary.
Contact the dealer or
manufacturer to arrange
for replacement or repair as
necessary.
Proceed as in A
Check the thermostat tempera-
ture setting.
Contact the dealer or
manufacturer to arrange
for replacement or repair as
necessary.
Connect the plug to the mains
socket.
Unplug the melter from the
power socket immediately.
Contact the dealer or
manufacturer to arrange for
replacement as necessary.
dip at least 2/3 of the probe
into the chocolate