Download Print this page

Troubleshooting - Martellato DigitalMeltinchoc MCD101 Handbook Of Use And Maintenance

Hide thumbs Also See for DigitalMeltinchoc MCD101:

Advertisement

PROGRAM
MELTING TEMPERATURES
DARK
MILK
WHITE
MANUAL
When selecting the program, it is possible to vary the chocolate pre-set temperature manually in
the following way:
Keep the key pressed (first arrow on the left), the temperature will start to flash, with the arrows
move up or down to reach the desired temperature, press the Set key to confirm the temperature.
It is possible to select the MANUAL mode setting the temperature parameters most suitable to
your requirements.
Every time the melter is restarted, it goes back to its default settings, that is the pre-set ones.
NB: do not use DigitalMeltinchoc without chocolate in the pan.
14
PROGRAMS
HOLDING TEMPERATURE
[°C]
[°C]
45
31
45
29
45
28
45
TO BE SET
DPLMCD - ENGLISH

7.0 TROUBLESHOOTING

FAULT
POSSIBLE CAUSE
A
The power ON light does not
No power to 230V
come on when the switch is
socket
pressed.
Electrical system protection has
tripped (thermal-magnetic circuit
breaker, circuit breaker, residual
current device).
Programming board
B
The melter and top surface of
No mains power
the appliance remain cold to the
touch.
Operating temperature set too
low
Break in heating element.
Break in power cable.
C
The melter fails to reach the re-
Intermittent contact in
quired temperature.
socket / plug connection.
Intermittent contact inside the
appliance.
REMEDY
power
1. Unplug the power cable.
AC
2. Check that the fault is not
attributable to the melter.
3. If it is a fault with the electrical
system, call in a professional
electrician to make the necessary
repairs.
4. Plug the appliance back in and
turn it back on.
5. If it is the melter that has
caused the electrical system
protection to trip, contact the
dealer or manufacturer to arrange
for replacement or repair as
necessary.
Contact the dealer or
manufacturer to arrange for
replacement or repair as
necessary.
Proceed as in A
Check the thermostat temperatu-
re setting.
Contact the dealer or
manufacturer to arrange for
replacement or repair as
necessary.
Connect the plug to the mains
socket.
Unplug the melter from the
power socket immediately.
Contact the dealer or
manufacturer to arrange for
replacement as necessary.
DPLMCD - ENGLISH
15

Advertisement