( KV-25 inch only)
@
Operation of BMC (Hexapole) Magnet
RG
8
R
G
B
R
GB
O-O-—-0
<> 0—0-—_0
<a 0-0-0
The
respective
dot
positions
resulting
from
moving
each magnet
interact, so be sure
to
perform adjustment while tracking.
Use the H.STAT VR to adjust the red, green, and
blue dots so they coincide at the center of screen
(by moving the dots in the horizontal direction).
(2) Dynamic Convergence Adjustment
3. Move the deflection yoke for best
Preparation:
-
convergenceas shown below.
@ Before starting perform Horizontal and Vertical
4. Tighten the deflection yoke screw.
static convergence Adjustment.
5. Install the deflection yoke spacers.
1. Slightly loosen deflection yoke screw.
2. Remove deflection yoke spacers.