Basic Specifications - Viking DBCV3638 Installation Manual

Designer series built-in custom ventilator system
Hide thumbs Also See for DBCV3638:
Table of Contents

Advertisement

BASIC SPECIFICATIONS

INTERIOR AND EXTERIOR POWER BUILT-IN WALL CUSTOM VENTILATOR SYSTEMS
RECOM.
1
DESCRIPTION
CFM
30"W.
300 int./440 int.
900 ext./ 1200 ext.
36"W.
300 int./440 int.
900 ext./ 1200 ext.
42"W.
440 int./
900 ext./ 1200 ext.
48"W.
880 int./
1200 ext.
1500 ext.
INTERIOR AND EXTERIOR POWER BUILT-IN ISLAND CUSTOM VENTILATOR SYSTEMS
RECOM.
1
DESCRIPTION
CFM
36"W.
440 int.
900 ext./1200 ext.
42"W.
440 int./
900 ext./
1200 ext./1500 ext.
54"W.
880 int./
1200 ext./ 1500 ext.
MODEL NUMBER
For Use with hoods:
DIV300 (interior)
DIV440 (interior)
DIV880 (interior)
DEV900 (exterior)
DEV1200 (exterior)
DEV1500 (exterior)
*Must use 8" duct from canopy to ceiling - transition to 10" duct past duct cover
PROPER INSTALLATION/DUCTING IS EXTREMELY IMPORTANT TO ENSURE MAXIMUM PERFORMANCE FROM ANY
VENTILATION PRODUCT
1. •All CFMs stated are based on tests at .1 static pressure: without applying static pressure, CFM would be greatly
overstated.
2. •Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained
installer.
•Straight runs and gradual turns are best; for example, each 90
straight run.
•Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
•Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
•Check with a qualified and trained installer or local codes for makeup air requirement, if any.
3. •Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-
wire with ground.
NUMBER OF
HALOGEN
FILTERS
LIGHTS
2
2
2
2
NUMBER OF
HALOGEN
FILTERS
LIGHTS
4
4
4
CFM
1
300
440
880
900
1200
1500
3
SPACERS
2
1
2
1
3
2
3
2
SPACERS
2
1
2
2
3
2
RECOMMENDED
DUCT SIZE
7" round
7" round
10" round
10" round*
10" round
10" round
elbow is equivalent to 5-10 feet (1.52 - 3.05 m) of
o
120VAC/60Hz
3
MAX. AMPS
(Interior/Exterior)
1.7/3.2
6.6/ 3.9
1.7/3.2
6.6/ 3.9
3.2
6.6/ 3.9
5.6/
4.3/
5.1
120VAC/60Hz
3
MAX. AMPS
(Interior/Exterior)
4.0/
7.5/5.2
4.0/
7.5/
5.2/ 6.0
6.4/
5.2/ 6.0
MAX. DUCT
2
RUN
(ft.)
50
50
50
50
50
75

Hide quick links: