Technical Data; Acs 763/863; Ambient Temperature; Humidity - Bosch ACS 763 Manual

Hide thumbs Also See for ACS 763:
Table of Contents

Advertisement

10. Technical data

10.1

ACS 763/863

Characteristic
Compressor
Dimensions (height x width x depth)
with HMI in shipping position
Color LCD display with LED backlight 7" TFT WVGA (800 x 480)
Filter
Humidity, RH without condensation
Gauge (EN 837-1 Class 1)
Maximum pressure (PS)
Sound pressure level at the operator's
workstation according to EN ISO 11204
Operating voltage, Frequency
Bottles
Minimum-maximum temperature (TS) -10 °C – 120 °C
Power
Pump capacity in free air
Service hoses
Cylinder capacity (V)
Cylinder operating capacity
Weight (empty cylinder + accessories) 112 kg
Degree of pollution
Overvoltage category
Degree of protection
Refrigerant / Group
WLAN (USB Dongle)
Heater belt
(only for ACS 863-OE)
10.2

Ambient temperature

Characteristic
Storage and transport
Operation
10.3

Humidity

Characteristic
Storage and transport
Operation
10.4

Electromagnetic compatibility

This product complies with EMC 2014/30/EU and in
particular with EN 61326-1.
Robert Bosch GmbH

11. Glossary

A/C system:
the air conditioning system of the vehicle on which to
Value/range
carry out maintenance.
1/4 HP
105 x 75 x 77 cm
Evacuation:
removal of condensate and other non-condensable
substances from an A/C system through a vacuum
150 kg (331 lb)
pump.
32,2 °C (90 °F), 86%
Ø 100 mm
Internal tank (ISV):
25 bar (2.5 MPa)
the refillable container of the station, intended to
< 70 dB(A)
contain the refrigerant; it has operational capacity of
17.4 kg.
230 Vac/1, 50/60 Hz
4x250 ml
Leak check (vacuum):
evacuation of the A/C system containing refrigerant
1100 W
6 CFM (170 l/m) 50/60 Hz
and pressure monitoring to detect a possible increase,
250 cm / SAE J2888
possible indication of a leak.
22 l
17.4 kg R1234yf
Rechargeable quantity:
the amount of refrigerant contained in the internal tank,
2
which can be loaded into the A/C system of a vehicle.
II
IP20
Recoverable quantity:
R1234 / 1
the total amount of additional refrigerant that can be
WLAN 802.11 b/g
recovered in the internal tank.
2,4 GHz
< 20 dBm
Leak check:
230 Vac, 400 W,
pressurization of components that contain refrigerant
60 °C thermal switch
and pressure monitoring to detect a possible decrease,
possible indication of a leak.
Recovery / recycling:
Value/range
refrigerant extraction from an A/C system, filtration and
-25 °C – 60 °C
transfer to the internal tank.
-13 °F – 140 °F
10 °C - 50 °C
PAG / POE:
50 °F – 122 °F
different types of oil in the vehicle A/C system
depending on the vehicle manufacturer.
R1234yf:
Value/range
refrigerant.
<75 %
<90 %
Technical data | ACS 763/863 | 83
SP00D00490
en
|
2020-01-08

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs 863

Table of Contents