TROUBLE SHOOTING
Case
The indoor unit gives out odour.
The outdoor fan rotates while the air
conditioner is not in operation.
The operation stopped suddenly.
(operation lamp is on)
"
" is displayed on the remote
controller, and the displayed contents flash
for several seconds when an operation
button is pressed.
When three short "beep" sounds are issued
in the case of wireless remote controller.
COOL cannot be changed over.
• When the display shows "
(changeover under master control),
it shows that this is a slave remote
controller.
When a long "beep" sound is issued in
the case of wireless remote controller.
The liquid crystal of the remote
controller shows "
after the power supply is turned on.
The compressor in the outdoor unit does
not stop after a short heating operation.
The inside of an outdoor unit is warm
when the unit has stopped.
When the air conditioner has not been used
(the power has been off) for a long time.
Warm air exits the unit even though it is off.
You can feel hot air coming out of the unit.
Call the service shop immediately.
„ When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF.
Continued operation in an abnormal condition may result in troubles, electric shocks or fire.
Consult the service shop where you bought the air conditioner.
„ Do not attempt to repair or modify the air conditioner by yourself.
Incorrect work may result in electric shocks or fire.
Consult the service shop where you bought the air conditioner.
If one of the following symptoms takes place, call the service shop immediately.
„ The power cord is abnormally hot or damaged.
„ An abnormal sound is heard during operation.
„ The safety breaker, a fuse, or the earth leakage breaker cuts off the operation frequently.
„ A switch or a button often fails to work properly.
„ There is a burning smell.
„ Water leaks from the indoor unit.
„ After a power failure
The air conditioner automatically resumes operation in
about 3 minutes. You should just wait for a while.
15
„ This happens when smells of the room, furniture, or cigarettes are
„ After operation is stopped:
„ While the air conditioner is not in operation:
„ For system protection, the air conditioner may stop operating on a sudden
• The air conditioner is controlled by the central equipment.
Flashing of the displayed contents indicates that the remote controller is
invalid for control.
• Refer to page 12.
"
• This shows that the remote controller is in normal condition.
" immediately
This continues for one minute.
• This is to prevent oil and refrigerant from remaining in the compressor.
The unit will stop after 5 to 10 minutes.
• This is because the crankcase heater is warming the compressor even
while the outdoor unit is stopped so that the compressor can start smoothly.
• For protecting the mechanism, supply the power for 6 hours at first, then
operate the air conditioner.
• Multiple units are operating on the same system, so if a unit in another
room is operating, some refrigerant will flow through the stopped units, too.
absorbed into the unit and discharged with the airflow.
(If this happens, we recommend you to have the indoor unit washed by a
technician. Consult the service shop where you bought the air conditioner.)
• The outdoor fan continues rotating for another 60 seconds for system protection.
• When the outdoor temperature is very high, the outdoor fan starts
rotating for system protection.
large voltage fluctuation.
It automatically resumes operation in about 3 minutes.
WARNING
„ Lightning
If lightning may strike the neighbouring area, stop
operation and turn the breaker OFF for system protection.
Explanation
Turn the breaker
OFF and call the
service shop.