PRACTICAL ADVICE FOR USING THE BURNERS
This hob has burners of different diameters. For better burner performance,
please stick to the following
rules:
Use pots and pans with bottoms the same width as that of the burners or
slightly larger (see table on the
right).
Only use flat-bottomed pots and pans.
Use the correct amount of water for cooking foods and keep the pot
covered.
Make sure pots on the grates do not protrude beyond the edge of the hob.
IMPORTANT: improper use of the grids can result in damage to the hob: do
not position the grids upside down or slide them across the hob.
Do not use:
Cast iron griddles, ollar
stones,
terracotta pots and
pans.
Heat diffusers such as meta I
mesh,
or any other types.
Two
burners simultaneously for one receptacle
(e.g.
fish
kettle).
HOW
TO USE THE HOB
Burner
Rapid
Semi-rapid
ffi
WARNING
Do not let the burner flame extend beyond the edge of the pan.
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame
setting.
Press the knob against the control panel to ignite the
burner.
Pot0
From 24 to 26 em
From 16to 22 em
After the burner has ignited, keep the knob pressed for about
5-l
0 seconds to allow proper device operation.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids,
etc.).
The knob must not be pressed for more than 15
sec.
lf, after that time has elapsed, the burner does not remain lit,
wait at least one minute before trying
to
light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner
difficult,
it is advisable to repeat
the operation with the knob turned to small flame
setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up
enough.
In this
case, repeat the operations described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
J
NOTE: in case of installation of a hood above the cooktop,
please refer to the hood instructions for the correct
distance.
i :
I
l'i
I
1
I
1:•
;
I ,
I
,•,. I
400
min.
INJECTORS TABLE
Type of gas used
Type of burner
NATURAL GAS
Rapid
(Methane}
G25
Semi-rapid
LIQUEFIED
Rapid
PETROLEUM GAS
(Cylinder) G30/G31
Semi-rapid
Type of gas used
Model
configuration
G2525 mbar
4 burners
G30/G31 30 mbar
4 burners
ELECTRIC SUPPLY: 230 V- 50 Hz
CATEGORY 112L3B/P
Injector
Rated thermal
Rated
Reduced heat
Gas pressure
I
marking
flow rate
consumption
capacity
mbar
kW
kW
min.
rat.
max.
132
c
3.00
3321/h
0.60
20
25
30
100
1.65
1831/
h
0.35
86
3.00
218g/h
0.60
25
30
35
65
1.65
120 g/h
0.35
Rated thermal
Total rated
Air required {m
3 )
for
flow rate {kW)
consumption
burning 1 m
3
of gas
7.95
881 1/h
8.187
7.95
578
g/
h
30.94