DIAGNOSTICS AND TROUBLESHOOTING
Failure
Error
Likely Failure Condition
F9
E0
Product not wired
correctly
F6
E1
Over temperature
(main/upper oven)
JennAir® 60 cm Built-In Steam Oven
1-6
n
For Service Technician Use Only
Suggested Corrective Action Procedure
1. Unplug oven or disconnect power. Check the wire connection from the home power
supply to the conduit according to the installation instructions. Reassemble all parts
and panels and plug in oven or reconnect power. If the error code does not appear,
follow the
"Final
2. If the error code does appear, unplug oven or disconnect power.
3. Check the wire connection from the conduit to the terminal block. Reassemble all
parts and panels and plug in oven or reconnect power. If the error code does not
appear, follow the
4. If the error does appear, unplug oven or disconnect power. Change the AM control.
Reassemble all parts and panels and plug in oven or reconnect power. If the error
code does not appear, follow the
5. If the error code does appear, unplug the oven or disconnect power. Change the
main harness. Reassemble all parts and panels and follow the
NOTE: One minute after error code F6E1 appears, F3E0 will also show.
1. Unplug oven or disconnect power. Check the sensor probe cable and connector
(J62). Check the whole board connection harness for any loose or damaged
connectors. If there are loose ones, fit them in their proper place.
2. Replace the sensor or harness if they are damaged. Reassemble all parts and
panels. Plug in oven or reconnect power. If the error code does not appear, follow
the
"Final
Steps" section.
3. If nothing is loose or damaged, turn the power off. Turn back on after 10 seconds
and start a cooking cycle with the grill level on "High" power. Wait for 15 minutes,
and if the error codes does not appear, turn off the oven and follow the
"Final
Steps" section.
4. If the error code appears during the 15 minutes, unplug oven or disconnect power.
Replace the AM control board.
5. Reassemble all parts and panels and follow the
Steps" section.
"Final
Steps" section.
"Final