Page 2
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
IC-TD002 assemblies. Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system. Product Certifications website, rok.auto/certifications. Provides declarations of conformity, certificates, and other certification details. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 6
Notes: Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Only connect the USB device for initial setup and maintenance. Disconnect the USB device once the initial setup or maintenance is complete. Keep the front access panel closed when the USB device port and USB key are not in use. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Classe I, Division 2, Groupes A, B, C et D . • Classe II, Division 2, Groupes F et G . • Classe III, Division 1 . • non dangereux. La mise en garde suivante s’applique à une utilisation en environnement dangereux. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
The maximum total inductance, L nd cable inductance of each i (peripheral), a separate USB peripheral device shall be less than or equal to L a (USB). L i (peripheral) cable a (USB) Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
L cable If cable capacitance and inductance are not known, the following values may be used: = 60 pF/ft (197 pF/m) cable = 0.20 µH/ft (0.66 µH/m) cable Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
• Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 • NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Follow standard safety practice and redundancy in the application of this product. • When mounted, the product cannot be tilted more than 60° from vertical. 60° 60° from Vertical from Vertical Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Touch screen serial cable (only for industrial performance monitors with touch screen display) • USB cable • Cable retention tie wraps • Installation instructions, publication 6186M-IN002 • Accessories CD that contains the installation files for monitor drivers and the ScreenSet monitor setup utility Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Bench or Table Mount M4 x 0.7 screws (quantity of 4) #2 Phillips torque screwdriver DIN rail bracket, catalog number 6189V-MPSDIN DIN rail DIN Rail Mount for AC Adapter #2 Phillips torque screwdriver Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
2. Cut the marked area with the appropriate cutting tools for the panel material. Take precautions so metal cuttings do not enter components that are already installed in a panel. 3. Remove any debris from the cutout. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Figure 10 to provide a proper seal and help prevent damage to the product. Rockwell Automation assumes no responsibility for water or chemical damage to the product or other equipment within the enclosure because of improper installation. 7. Repeat the torque sequence at least three times until all mounting clips are torqued to 1.35 N·m (12 lb·in) and the sealing gasket is compressed uniformly against the panel.
2. Alight the industrial performance monitor with the VESA interface of the arm. 3. Insert four M4 x 0.7 screws through the VESA interface and into the mounting holes on your industrial performance monitor. 4. Tighten the four M4 x 0.7 screws. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
6. Insert the upper lip of the DIN rail bracket on the top edge of the DIN rail (5). 7. Press the AC adapter firmly against the lower edge of the rail (6). 8. Tighten the fastener on the DIN rail bracket (7). Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 24
Chapter 3 Mount Notes: Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
1. Connect the pinned end of the supplied DVI cable to the DVI video port on your performance monitor. 2. Connect the other end of the DVI cable end to the output of any DVI video source. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
DB-9 Socket End Not Connected (DCD) Transmit Data (TXD) Receive Data (RXD) Data Terminal Ready (DTR) Common Signal Return (SG) Not Connected (DSR) Request to Send (RTS) Clear to Send (CTS) Not Connected Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
• Do not use the AC adapter and external DC simultaneously. • Power must be available with a ground connection nearby. Whenever possible, connect your performance monitor to the same AC source that supplies your industrial computer. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
If you use the functional ground screw, use a 1.5 mm (16 AWG) or larger external wire to connect the product to earth ground (2). Use a ground wire with green insulation and a yellow stripe for easy identification. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
To check the current display resolution or change it, access the ‘Display’ settings in the ‘Control Panel’ from the OS. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
The default setting varies by display size and LCD model used. Perform the following steps to adjust the brightness. If the monitor brightness is set higher than the factory default setting, the life of the LCD display is reduced. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Your performance monitor stores the set-up information for each video mode. If you have difficulty reading the display during the starting video modes, press the ‘Auto Adjust’ button during the starting video modes. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Accesses functions to auto-adjust the display settings or manually adjust the horizontal Image and vertical image position, frequency phase, and width level. Tools Accesses functions to adjust the OSD, reset factory settings. Exit Exits the OSD main menu. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 35
See Use the Control Buttons on page 30 for instruction. ATTENTION: When the brightness is adjusted higher than the factory default setting, the life of the LCD is reduced. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 36
Sets the white point/color temperature that is based on degrees Kelvin (K): • 4200 • 5000 Temperature 4200…9300 • 6500 = typical personal computer • 7500 • 9300 = typical television and monitor default setting Back Returns to the Color menu — Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 37
Table 18 - Tool Menu Factory Reset Back Function Description Accesses the OSD submenu (see Table 19 on page Factory Reset Resets all OSD settings to factory defaults Back Returns to the OSD main menu Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 38
(1) The term ‘Rotation’ is the screen rotation, not the physical rotation of your industrial performance monitor. Your industrial performance monitor cannot be physically tilted more than 60° from its vertical as stated in Installation Guidelines on page 15 Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Lightly dampen a microfiber cloth with water or a cleaner made specifically for cleaning LCD display surfaces. b. Gently wipe the LCD display with as little pressure as possible. c. Press the power button to apply power to your industrial performance monitor. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
You must uninstall your industrial performance monitor and place it in its original packing material before shipping. Rockwell Automation is not responsible for any damage to an industrial performance monitor that is shipped or transported while installed in a machine, panel, or rack.
Check with local health and sanitation agencies for ways to dispose of equipment properly. The backlight assembly in this unit contains mercury. At the end of its life, your performance monitor must be collected separately from any unsorted municipal waste. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Test the power outlet by plugging in a properly functioning device. Replace the suspected faulty cable or power cord. Have the performance monitor serviced. See Shipment and Transport on page 38 for information. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 44
Press and hold both brightness buttons (on the back side of your performance monitor) for at least 3 seconds to pressed.. unlock the OSD menu. See Table 10 on page 30 for the location of these buttons. Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Red Video Green Video Blue Video Not Used Hot Plug Detect Red Video Ground Green Video Ground Blue Video Ground VGA Power Not Used Not Used DDC Data Horizontal Sync Vertical Sync DDC Clock Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Not Used Hot Plug Detect Not Used DATA0– DDC Clock DATA0+ DDC DATA DATA 0 Shield Not Used Not Used DATA1- Not Used DATA1+ Clock Shield DATA 1/3 Shield Clock+ Not Used Clock– Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
1700M Models 1 back side (host computer port) Type B USB port Front side (aluminum bezel only): 1 quantity Type A USB 2.0 port Back side: 2 quantity 500 mA per port Current capacity Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
UL Listed Class I, Division 2, per ISA 12.12.01 (when marked on the nameplate) cUL Listed Class I, Division 2, per CSA No. 213 (when marked on the nameplate) CE marked for all applicable directives RoHS compliant Certifications C-Tick China RoHS Türkiye RoHS Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 49
6186M Industrial Performance Monitors User Manual Notes: Rockwell Automation Publication 6186M-UM002C-EN-P - December 2023...
Page 50
At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Allen-Bradley, expanding human possibility, Rockwell Automation, and Screenset are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc.
Need help?
Do you have a question about the Allen-Bradley 6186M Series and is the answer not in the manual?
Questions and answers