Download Print this page

Entering The Programming Mode - Viking K-202-DVA Technical Practice

Two-input voice alarm dialer

Advertisement

P
r
o
g
r
a
m
m
P
r
o
g
r
a
m
m
A. Entering the Programming Mode
1. Local
Step 1.
Move the PROG/NORM switch to PROG and plug an analog phone into the TELCO jack.
Step 2.
After taking the phone off hook, wait for two beeps.
Step 3.
Program as shown in sections B-T.
Step 4.
To exit programming, hang-up. Set the PROG/NORM switch to NORM.
2. Remote
Step 1.
Make sure the PROG/NORM switch is set to the NORM position and that there is a CO line or analog PABX/KSU
extension in the TELCO jack.
Step 2.
Call into the K-202-DVA on that line or extension. The unit will answer after the set ring delay (see Programming
section F) and a single beep should be heard.
Step 3.
Enter a
should be heard.
Note: The security code must be entered within 20 seconds otherwise the K-202-DVA will time out and hang up.
When in programming, if 20 seconds elapse without Touch Tones being entered or a message being recorded, the
K-202-DVA will automatically exit programming and hang up.
Step 4.
Program as shown in sections B-T.
Step 5.
To exit programming, hang-up. After the 20 second timeout has elapsed, the K-202-DVA will be ready for normal
operation. Alternatively, dial ##7 and the K-202-DVA will immediately be ready for normal operation.
Note: Correct programming entries are implemented and then acknowledged by two beeps. Incorrect programming
entries are discarded and receive three beeps to indicate an error.
B. Quick Programming Features
To enter phone numbers for each input ....................................................................
To clear a phone number .........................................................................................
To enter pager numbers ...........................................................................................
To play message for either input ..............................................................................
Contacts: First digit - 0 = NO, 1 = NC , 2 = enabled, 3 = disabled
Second Digit - 0 = momentary closure, 1 = continuous closure ..............
Repeat/Lap Counter: First two digits - message repeat counter (01-99)
Last two digits - lap counter (01-99) ......................................
To program the Qualifier Timer (HHMMSS, 18 hour maximum) ...............................
To program the Resume Operation Timer (HHMMSS, 18 hour maximum) ...............
To program the Security Code .................................................................................
To program the Access Code ...................................................................................
To program the Ring Delay (0-9) ...............................................................................
To program the Ringback Limit ................................................................................
To program the Forced Play Timer (01-99 seconds) (00 = clear) .............................
To record messages for each input (1-2) ..................................................................
To clear one message ..............................................................................................
To add a 4 second pause anywhere in the dialing string ...........................................
,
To add a
anywhere in the dialing string .................................................................
To add a # anywhere in the dialing string ..................................................................
To set to normal dialing speed ..................................................................................
To set to fast dialing speed .......................................................................................
To program no hookswitch flash before dialing ........................................................
To program a 500ms hookswitch flash before dialing ..............................................
To disable the PA (public address) mode ..................................................................
To enable the PA (public address) mode ...................................................................
To hang up ................................................................................................................
To return programming to defaults ............................................................................
* X is an input number (1 or 2) and Y is one of the 7 phone numbers (1-7) that can be dialed for this input.
4
i
n
g
i
n
g
,
and the six-digit security code (factory default is 845464). If the correct code is entered, two beeps
- then - Enter Memory Location
Enter Digits
1-32 digits
then
(no digits)
then
1-32 digits
then
,
0X*
2 digits
then
4 digits
then
6 digits
then
6 digits
then
6 digits
then
6 digits
then
1 digit
then
2 digits
then
2 digits
then
,
,
1 -
2
,
,
then immediately press any digit
1 -
2
,
9
,,
,
#
##1
##2
##3
##4
##5
##6
##7
###
#XY*
#XY*
,
#
XY*
#X9*
#X0*
,
#X
*
#X#*
#90
#91
#92
#93
#94

Advertisement