Nominal current at nominal voltage. Max rated current at worst case supply voltage. *Special 12Vdc option is available – Contact E2S sales Table 1: Electrical Ratings. Ensure the system power supply is capable of providing the maximum current required for all sounders. Review associated cable size, length and quantity of sounders on each circuit.
Page 2
Temperature Classification for Gas Applications 3) Marking & Rating Information All units have a rating label, which carries the following important information. Products may have further approvals, see E2S website for 100ºC further details. 85ºC ATEX / IECEx / UKEX Ratings...
INSTRUCTION MANUAL GNExS1 Alarm Horn Sounder with relay / telephone initiate For use in Flammable Gas Atmospheres 5) Special Conditions for Safe Use 6.2 Access to the Flameproof Enclosure Repair of the Flame Path is not permitted. Warning – Hot surfaces. External...
Page 4
EN 60079-14 / IEC60079-14. Blanking Plugs Figure 5: GNExS1 Entries and Terminal Block Location. When only one cable entry is used the other entries must be When connecting wires to the terminals great care should be...
Page 5
INSTRUCTION MANUAL GNExS1 Alarm Horn Sounder with relay / telephone initiate For use in Flammable Gas Atmospheres M20 to ½” NPT 8.2 Activation, Relay / Telephone Wiring Inputs and M20 to ¾” NPT Signal Type Header Setting (H1) M20 to M25 It is important to note that stopping plugs cannot be fitted onto The H1 header selection configures the activation signal type.
Page 6
INSTRUCTION MANUAL GNExS1 Alarm Horn Sounder with relay / telephone initiate For use in Flammable Gas Atmospheres 8.4 Unit Latch mode duration DIP switch S1 setting 10) Maintenance, Overhaul and Repair Maintenance, repair and overhaul of the equipment should The relay/telephone latch duration setting is only applicable...
Page 8
16/03/2023 WRITTEN CONSENT. IMPRESS HOUSE STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER ALTERNATIVE MATERIAL AS PER LATEST DATE OF ISSUE SHOWN ABOVE LONDON W3 7QH SCALE SHEET APPROVED DATE ALERTALARM RANGE D250-06-001 WWW.E2S.COM NTS 1 16/03/2023 R.N.POTTS...
Other Standards and Regulations EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-038_Issue_F (GNExS, GNExL) - Page 1 of 2 -...
Page 10
This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-038_Issue_F Quality Assurance Manager Date and Place of Issue: London, 23/12/2020 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-038_Issue_F (GNExS, GNExL) - Page 2 of 2 - QAF_252_Issue_5...
Page 11
This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-095_Issue_A Quality Assurance Manager Date and Place of Issue: London, 04/02/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-095_Issue_A (GNExS, GNExL) - Page 1 of 1 QAF_252_Issue_5...