Download Print this page
E2S GNExCP7-BG-I Instruction Manual

E2S GNExCP7-BG-I Instruction Manual

Intrinsically safe call point

Advertisement

Quick Links

INSTRUCTION MANUAL
GNExCP7-BG-I, GNExCP7-BG-IR
Intrinsically Safe Call Point
Class I Div 1 ; UL60947
NEC / CEC / ATEX / IECEx / UKEx Zone 0, 1, 2
1) Product Table
2) Warnings
WARNINGS:
 DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
 DO NOT OPEN WHEN ENERGISED
ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH.
AVERTISSEMENT:
 NE PAS OUVRIR UN PRESENCE D'ATMOSPHERE EXPLOSIVE
 NE PAS OUVRIR ENERGIE
 DANGER POTENTIEL CHARGE ÉLECTROSTATIQUE - NETTOYER UNIQUEMENT AVEC UN CHIFFON HUMIDE
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D202-00-501-IS
Unit Type Code
Ui
Ii
GNExCP7-BG-I
Pi
Ci
GNExCP7-BG-IR
Li
Table 1: Electrical Ratings
Issue 1
28-01-2024
GNExCP7-BG-I &
GNExCP7-BG-IR
Input Parameters
=
30V
=
500mA
=
1100mW
=
0
=
0
www.e2s.com
Sheet 1 of 9
Tel: +44 (0)208 743 8880

Advertisement

loading
Need help?

Need help?

Do you have a question about the GNExCP7-BG-I and is the answer not in the manual?

Questions and answers

Summary of Contents for E2S GNExCP7-BG-I

  • Page 1 INSTRUCTION MANUAL GNExCP7-BG-I, GNExCP7-BG-IR Intrinsically Safe Call Point Class I Div 1 ; UL60947 NEC / CEC / ATEX / IECEx / UKEx Zone 0, 1, 2 GNExCP7-BG-I & GNExCP7-BG-IR 1) Product Table Unit Type Code Input Parameters 500mA GNExCP7-BG-I...
  • Page 2 Class A & B (all locations) Model No: Rating Vibration: Class A (all locations except installation on machinery such as combustion engines, GNExCP7-BG-I Class I Div 1 Group ABCD T6 Ta -55°C to compressors, pumps, including piping on +70°C such machinery) EMC: Class A &...
  • Page 3 Temperature Classification for Gas Applications weight of the unit. To gain access to the mounting holes in the base the front cover must be removed. See Section 7 100ºC (GNExCP7-BG-I) only 85ºC (GNExCP7-BG-I) only Equipment Category Equipment Protection Level Ga, Gb, Gc Ambient Temperature Range -55°C to +70°C (-67°F to +158°F) ATEX/IECEx/UKEx...
  • Page 4 Internal Earthing For models GNExCP7-BG-I: Max. ambient temperature ºC req. Cable / Cable Gland rating: ºC...
  • Page 5 For EOL and Series device limitations and configurations see For model GNExCP7-BG-I: Section 15. Fitting can be requested by E2S at the order stage or added to the correct terminal blocks afterward. All Max.
  • Page 6 EOL only for alternative EOL wiring achieve this. Component Lead Bending Component Lead Bending _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D202-00-501-IS Issue 1 28-01-2024 Sheet 6 of 9...
  • Page 7 Failure to open a contact when the call point is struck with specified force  Spurious output despite no input _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D202-00-501-IS Issue 1 28-01-2024 Sheet 7 of 9...
  • Page 8 Fig. Single stage call point alarm using single galvanic isolator. Fig. Single stage call point alarm using single barrier. _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D202-00-501-IS Issue 1 28-01-2024...
  • Page 9 Ccable = 60 pF/ft., Lcable = 0.2 μH/ft. _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D202-00-501-IS Issue 1...
  • Page 10 WRITTEN CONSENT. STANDARDS MANSELL ROAD ACTON DRAWING NUMBER GNExCP7-I and STExCP8-I units EUROPEAN SAFETY SYSTEMS LTD. SCALE SHEET ALTERNATIVE MATERIAL LONDON W3 7QH APPROVED DATE AS PER LATEST DATE OF ISSUE SHOWN ABOVE with DIN Rail D202-06-501 02-02-2024 R.N.POTTS WWW.E2S.COM...
  • Page 11 B.ISARD WRITTEN CONSENT. STANDARDS MANSELL ROAD ACTON GNExCP7-IR and DRAWING NUMBER ALTERNATIVE MATERIAL EUROPEAN SAFETY SYSTEMS LTD. SCALE SHEET LONDON W3 7QH APPROVED DATE STEXCP8-IR units AS PER LATEST DATE OF ISSUE SHOWN ABOVE D202-06-502 with PCB 02-02-2024 WWW.E2S.COM R.N.POTTS...
  • Page 12: Eu Declaration Of Conformity

    This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-115_Issue_A Quality Assurance Manager Date and Place of Issue: London, 29/02/2024 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-115_Issue_A - Page 1 of 1 - QAF_252_Issue_5...
  • Page 13 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-117_Issue_A Quality Assurance Manager Date and Place of Issue: London, 29/02/2024 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-117_Issue_A - Page 1 of 1 - QAF_252_Issue_5...