Radial alarm horns for use in hazardous locations - dust (6 pages)
Summary of Contents for E2S GNExCP7-BG-I
Page 1
INSTRUCTION MANUAL GNExCP7-BG-I, GNExCP7-BG-IR Intrinsically Safe Call Point Class I Div 1 ; UL60947 NEC / CEC / ATEX / IECEx / UKEx Zone 0, 1, 2 GNExCP7-BG-I & GNExCP7-BG-IR 1) Product Table Unit Type Code Input Parameters 500mA GNExCP7-BG-I...
Page 2
Class A & B (all locations) Model No: Rating Vibration: Class A (all locations except installation on machinery such as combustion engines, GNExCP7-BG-I Class I Div 1 Group ABCD T6 Ta -55°C to compressors, pumps, including piping on +70°C such machinery) EMC: Class A &...
Page 3
Temperature Classification for Gas Applications weight of the unit. To gain access to the mounting holes in the base the front cover must be removed. See Section 7 100ºC (GNExCP7-BG-I) only 85ºC (GNExCP7-BG-I) only Equipment Category Equipment Protection Level Ga, Gb, Gc Ambient Temperature Range -55°C to +70°C (-67°F to +158°F) ATEX/IECEx/UKEx...
Page 4
Internal Earthing For models GNExCP7-BG-I: Max. ambient temperature ºC req. Cable / Cable Gland rating: ºC...
Page 5
For EOL and Series device limitations and configurations see For model GNExCP7-BG-I: Section 15. Fitting can be requested by E2S at the order stage or added to the correct terminal blocks afterward. All Max.
Page 6
EOL only for alternative EOL wiring achieve this. Component Lead Bending Component Lead Bending _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D202-00-501-IS Issue 1 28-01-2024 Sheet 6 of 9...
Page 7
Failure to open a contact when the call point is struck with specified force Spurious output despite no input _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D202-00-501-IS Issue 1 28-01-2024 Sheet 7 of 9...
Page 8
Fig. Single stage call point alarm using single galvanic isolator. Fig. Single stage call point alarm using single barrier. _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D202-00-501-IS Issue 1 28-01-2024...
Page 10
WRITTEN CONSENT. STANDARDS MANSELL ROAD ACTON DRAWING NUMBER GNExCP7-I and STExCP8-I units EUROPEAN SAFETY SYSTEMS LTD. SCALE SHEET ALTERNATIVE MATERIAL LONDON W3 7QH APPROVED DATE AS PER LATEST DATE OF ISSUE SHOWN ABOVE with DIN Rail D202-06-501 02-02-2024 R.N.POTTS WWW.E2S.COM...
Page 11
B.ISARD WRITTEN CONSENT. STANDARDS MANSELL ROAD ACTON GNExCP7-IR and DRAWING NUMBER ALTERNATIVE MATERIAL EUROPEAN SAFETY SYSTEMS LTD. SCALE SHEET LONDON W3 7QH APPROVED DATE STEXCP8-IR units AS PER LATEST DATE OF ISSUE SHOWN ABOVE D202-06-502 with PCB 02-02-2024 WWW.E2S.COM R.N.POTTS...
This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-115_Issue_A Quality Assurance Manager Date and Place of Issue: London, 29/02/2024 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-115_Issue_A - Page 1 of 1 - QAF_252_Issue_5...
Page 13
This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-117_Issue_A Quality Assurance Manager Date and Place of Issue: London, 29/02/2024 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-117_Issue_A - Page 1 of 1 - QAF_252_Issue_5...
Need help?
Do you have a question about the GNExCP7-BG-I and is the answer not in the manual?
Questions and answers