Download Print this page

Epilog Laser Edge 12 Manual

Advertisement

Quick Links

Parts Required
LC0806 - PCBA, X-Axis Interface
!
An anti-static strap is required when working with any PCB in the Fusion
Edge and Fusion Pro engraver. This strap prevents the buildup and
accidental discharge of static electricity which can damage sensitive
electronic components.
X-Axis PCB Replacement
Edge 12, 24 & 36, Pro 24 & 36
01/2023
www.epiloglaser.com
tech@epiloglaser.com
Tools Required
5/32" Allen wrench
Phillips head screwdriver
Anti-static strap
303-215-9171
.

Advertisement

loading

Summary of Contents for Epilog Laser Edge 12

  • Page 1 303-215-9171 X-Axis PCB Replacement Edge 12, 24 & 36, Pro 24 & 36 Parts Required Tools Required • LC0806 - PCBA, X-Axis Interface • 5/32” Allen wrench • Phillips head screwdriver • Anti-static strap An anti-static strap is required when working with any PCB in the Fusion Edge and Fusion Pro engraver.
  • Page 2 17000 X-Axis PCB Replacement Using the Anti-Static Clamp Open Strap An anti-static strap is required when working with any PCB in the Fusion Pro engraver. This strap prevents the buildup and accidental discharge of static electricity which can damage sensitive electronic components.
  • Page 3 17000 X-Axis PCB Replacement X-Axis PCB Replacement 6. The preferred location to attach the alligator clip is the chassis bolt that connects to the ground from the X-Axis PCB Removal regenerative clamp, located behind the right panel of the engraver: 1.
  • Page 4 17000 X-Axis PCB Replacement 8. Loosen and remove the four (4) Phillip screws that secure the x-axis PCB to the x-axis assembly: 5. Place the anti-static strap around your wrist and attach the clamp to a bare metal surface in the machine. 6.
  • Page 5 17000 X-Axis PCB Replacement X-Axis PCB Installation 8. Loosen and remove the four (4) Phillip screws that secure the x-axis PCB to the x-axis assembly: 1. Place the anti-static strap around your wrist and attach the clamp to a bare metal surface in the machine.
  • Page 6 17000 X-Axis PCB Replacement 4. Connect the autofocus sensor harness and flex cable to the x-axis PCB: 5. Replace the right panel of the engraver. If further assistance is needed, please rech out to Epilog Tech Support by phone at 303-215-9171 or by email at tech@epiloglaser.com.

This manual is also suitable for:

Edge 24Edge 36Pro 24Pro 36