Download Print this page

Viking E-60 Series Technical Practice page 3

Double gang entry phones with led
Hide thumbs Also See for E-60 Series:

Advertisement

C. Surface Mounting
A Viking model VE-5x5 can be used to surface mount an E-60 to a wall, post or Viking model VE-GNP Gooseneck Pedestal (EWP model recommended), see DOD# 424 for more
information on the VE-5x5 and VE-GNP. Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or caulking. Route wire into the VE-5x5 box, secure-
ly screw it to wall or post and seal hole in box around wire with putty or caulking. Attach (2) junction box to double gang adapter plates (included with E-60) to top and bottom holes
of the VE-5x5 prior to mounting the E-60. Note: Conduit may also be used when surface mounting wire, but should not enter through the top of the VE-5x5. When routing wiring
from above, a drip loop is required. WARNING: Do NOT use a typical "wet location box" as not all styles seal properly with the E-60 faceplate.
D. Mounting the Faceplate
After the Rough-In box or VE-5x5 is securely mounted, caulking between the box and rough opening is completed (if required), and wires are con-
nected, remove paper liner from face plate gasket. While firmly holding the LED light pipe in the faceplate, carefully slide the faceplate gasket over
the back of the light pipe and press gasket to the back of the faceplate. Push the 1-1/4" 6-32 screws through faceplate holes and small holes in gas-
ket, the faceplate gasket should retain the screws. Position Circuit board mounting plate over screws. Align screws with single gang box bosses and
tighten face plate until gasket is fully collapsed and the push button is protruding through the clearance hole in the face plate. Included 1/4" thick
gasket will provide an adequate seal for most siding surfaces; however for rough surfaces (ie: brick, stucco, etc.) additional caulking may be required.
3.25"
5.22"
5.14"
3.63"
3.63"
2.25"
Optional VE-5x5 Surface Mount Box with Black
Satin Powder Paint Finish, not included (DOD# 424)
WARNING: Do NOT use a wet location box.
E. Wiring the E-60
VIKING
(Ring
connector
included)
** Earth
Ground
(optional)
Green
(Tip)
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC
!
outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
* Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Do not strip wires prior
to terminating.
** Note: To increase surge protection, loosen the PCB mounting screw labeled
Earth Ground (grounding rod, water pipe, etc.) After fastening ring treminal to PCB mounting screw, bend terminal up to avoid interference with single gang box.
*** Note: Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking Hot-Line Dialer. For more information, retrieve Fax Back Documents 317.
**** Note: When installing a line powered phone on a low voltage and/or low loop current phone system extension, a Viking
TBB-1A Talk Battery Booster may be required.
P
r
o
g
r
a
m
m
P
r
o
g
r
a
m
m
A. Adjusting Speaker Volume
The speaker volume pot can be adjusted to increase or decrease
the speaker volume to the level desired.
B. Adjusting the Microphone Volume
In certain noisy locations (background traffic, machinery or wind),
the microphone volume may need to be decreased. A symptom of
this is one-way talk path, in which the distant party cannot be heard
over the speaker. A microphone volume pot is provided for increas-
ing or decreasing the microphone volume. Note: If the microphone
volume is set too high or too low, one-way talk path may occur.
3.7"
Wide
Min.
*2.25"
-OR-
Deep
Min.
2.84"
Tall Min.
(2) Junction Box to
(4) Optional Dry Wall
Double Gang Adapter
Screws (not included)
Plates and (4) 5/64 Hex
"Old Work" Double Gang
Drive Flat Head Screws
Rough-In Box (Allied Molded
(included with the E-60)
9312 box shown, not included)
* CAUTION: Excessive wire length and/or using a
rough-in box with inadequate depth can apply force
to the circuit board causing physical damage.
Rear View of the
E-60 Circuit Board
Mounting Plate
* Gel-Filled
Butt Connectors
(included)
E-60 is not
polarity sensitive
Red
(Ring)
i
n
g
i
n
g
(2) Gel-Filled
Butt Connectors
(included)
Red
Green
Circuit Board
Mounting Plate
(included)
** Important: Push LED light pipe into faceplate hole, then place faceplate
upside down on a clean flat surface and push down on back side of plate
until light pipe is fully seated and straight. WARNING: Inserting the light pipe
more than one time can cause a loose fit.
Viking C-200 or C-2000B Entry
Phone Controller (not included)
VIKING
MODEL C-2000B
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7
8 9 10 11 12 13
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
J7-
J8-
J9-
J10-
J11-
1
3
1
2
1
2
3
1
2
3
3
2
3
1
2
LED1
LED2
LED3
C
LED4
C
LED5
C
LED6
C
LED7
C
C
C
-or-
(as shown above) and fasten a wire with ring terminal (included) from the mounting screw to
Microphone
Volume
(see section B)
DIP
Switches
ON
ON
OFF
1
2
3
4
1/4" Thick Foam
Facplate
Faceplate Gasket
(included)
(included)
*** Optional Viking
K-1900-5 Dialer
(not included)
**** C.O. Line
or Analog
VIKING
PABX/KSU Station
©
Programmable
(programmed for
Tone Dialer
MODEL: K-1900-5
ringdown)
Quick Programming Guide
1. Call the phone connected to the dialer.
2. Answer phone. Enter
& security code.
(Factory set to 845464) Write your
VIKING
security code below:
DLE-200B
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
Viking Electronics, Inc.
Hudson, WI 54016
LINE IN
PHONE
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
Need More Information on the TBB-1A?
?
Call (715) 386-4345 and select 630.
VIKING
** LED
Light Pipe
(included)
(4) 6-32 x 1.25" Long
5/64" Hexdrive
Flathead Screws
(included)
Viking DLE-200B
Two Way Ringdown
Circuit (not included)
RINGDOWN
©
1
2
RES
BUSY
Speaker
Volume
(see section A)
Rear View of the
E-60 Circuit Board
Mounting Plate
Note:
Pots and
DIP switches are
shown in factory
default settings.

Advertisement

loading

This manual is also suitable for:

E-60-ssE-60-bnE-60-pbE-60-whE-60-bk