Initial configuration

The first time the unit receives the power supply, it will enter into ASSISTANT mode. The display will show
flashing with 0.
the message
Step 1:
Select the most suitable InI option based on the type of installation to be carried out and press SET. The
available options will be shown in the following table:
Type of installation
InI
Cold regulation
0
Demo Mode: it displays the temperature but does not regulate the temperature or activate relays
1
Solenoid
2
Solenoid + compressor
3
Solenoid + compressor
4
Solenoid
5
Solenoid + compressor
6
Solenoid + compressor
7
Solenoid + compressor
8
Solenoid + compressor
9
Solenoid + compressor
10
Solenoid + compressor
11
Solenoid
12
Solenoid + compressor
13
Solenoid + compressor
* o00=2 in AK-RC 204B, o00=0 in AK-RC 205C
Note: If options 2, 5, 7, 9 or 12 are chosen, check the configuration of parameter I11 according to the pressure switch type used. (See
diagram included with the device).
Step 2:
to enter the desired Temperature Set Point value and press SET. The wizard has finished.
Use keys
and
The unit will begin to regulate the temperature.
If this is not the first time you use the wizard, after completing the last step the display will show the
message dFp (default parameters). You may choose between two options:
0: Only changing the parameters which affect the wizard. The other parameters will remain the same.
1: All parameters return to their factory setting except those which have been modified by the wizard.
Important: The wizard will not reactivate. To enter the wizard mode, initiate Stand-by mode by pressing the
wait until the unit completely halts the temperature regulation (the
sequence one after the other,
Warning: If the pump down function is active, a certain amount of time may elapse between starting the stand-by function and the
controller stopping.
© Danfoss | Climate Solutions | 2022.08
Pump
Evap.
Defrost
Down
fans
No
Electric
Yes
Yes
Electric
Yes
No
Electric
Yes
No
Air
Yes
Yes
Air
Yes
No
Air
Yes
Yes
Hot gas
Yes
No
Hot gas
Yes
Yes
Reversed cycle
Yes
No
Reversed cycle
Yes
No
Static
No
Yes
Static
No
No
Static
No
,
, SET.
Parameters
o00
I00
I10
I11
Pd
0
*
2
0
0
1
1
2
7
1
0
1
2
0
0
0
*
1
0
0
1
1
1
7
1
0
1
1
0
0
1
1
2
7
1
0
1
2
0
0
1
1
2
7
1
0
1
2
0
0
0
*
1
0
0
1
1
1
7
1
0
1
1
0
0
indicator will light up permanently) and press the following keys in
I20
I21
d1
d7
F3
0
0
20
0
0
0
0
20
0
0
0
0
20
0
0
0
0
20
1
1
0
0
20
1
1
0
0
20
1
1
9
1
5
2
0
9
1
5
2
0
0
0
5
3
0
0
0
5
3
0
0
0
20
1
-
0
0
20
1
-
0
0
20
1
-
key for 3 seconds and
AN41473467835501-000102 | 3
Diagram
to be
used
A
B
B
A
B
B
C
C
D
D
A
B
B

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Optyma AK-RC 204B and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Optyma ak-rc 205c

Table of Contents