Eaton DA/EDA 106 Operation And Maintenance Manual

Eaton DA/EDA 106 Operation And Maintenance Manual

Pressure filters, change-over

Advertisement

Operations and Maintenance Manual
for Eaton Pressure Filters, Change-Over
DA/EDA 106, 256, 406, 636, 1006, related specification
This manual contains operation and maintenance information for series DA/EDA 106, 256, 406, 636,
1006 and related specifications. For customer specific models, there are additional instructions on
those data sheets. The pressure filters listed above are intended for the filtering of liquid media.

1. Safety instructions

WARNING: Avoid injury. Read and understand this manual before operating the filter.
FAILURE TO FOLLOW THIS WARNING COULD LEAD TO DEATH, SEVERE INJURY, OR
PROPERTY DAMAGE. Eaton does not assume liability for any damage that occurs to due
misuse of equipment.
WARNING: This filter is a pressure vessel designed to operate under specific pressure,
temperature, and other engineering parameters. Follow the operating conditions specified
on each data sheet. Operating outside of these parameters can cause damage to important
pressure holding parts and sealing. Pay special attention to excess pressure, temperature
range, and operating fluid. The compatibility of filter components with the operating fluid
should always be considered before operation. USE OF INCOMPATIBLE MATERIALS
COULD LEAD TO PRODUCT FAILURE, LEAKAGE, DEATH, SEVERE INJURY OR
PROPERTY DAMAGE.
WARNING: Always wear safety goggles and gloves when working on the filter. Under
working conditions, the filter housing is pressurized. Do not try to loosen or remove any part
of the filter or the filter housing during operation. The operating fluid could escape at high
pressure and high temperatures. This does not apply to the offline vessel that is not under
operation. FAILURE TO FOLLOW THIS WARNING COULD LEAD TO DEATH, SEVERE
INJURY, OR PROPERTY DAMAGE.
WARNING: Leaking operating fluid can cause injury and burns. Equipment should be
shut down and isolated from energy sources and other equipment before any
inspection or servicing to prevent risk of shock or process fluid leakage. Do not open
the filter housing until you make sure it is not pressurized. The filter surface may be hot and
cause burns. When changing the filter, check the operating temperature before touching any
surface during operation. If you come into contact with the operating fluid, please follow the
safety instructions provided by the fluid manufacturer. FAILURE TO FOLLOW THIS
WARNING COULD LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
To ensure proper fit and function, only use Eaton spare parts.

2. Installation

The filter is supplied and delivered ready to be installed. The mounting position of the filter is vertical. The
filter has to be fitted with fastening screws in size and amount according to the corresponding fastening
bore holes of the filter housings. The filter should be mounted to minimize tensile forces on the filter
housing and change-over valve. The piping should be connected with flanges.
During installation ensure that:
-
No dirt and no impurities of foreign fluids penetrate the filter.
-
The connections for input and output are correctly attached to the pipe system.
-
The pipe system is connected to the filter to minimize stress on the filter.
-
Ensure the filter element is accessible for service and change out.
Clogging indicators should be installed according to the instructions on the unit specific data sheet and
the instructions in this manual.
Sheet No.
69750-4B
Page 1/4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DA/EDA 106 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton DA/EDA 106

  • Page 1 DA/EDA 106, 256, 406, 636, 1006, related specification Page 1/4 This manual contains operation and maintenance information for series DA/EDA 106, 256, 406, 636, 1006 and related specifications. For customer specific models, there are additional instructions on those data sheets. The pressure filters listed above are intended for the filtering of liquid media.
  • Page 2 8. Switch to the filter housing you would like to operate first by using the switch gear lever. 9. After finishing step 7, tighten the locking screws. After following these instructions for commissioning, the serviced filter vessel is ready for operation. DA/EDA 106-1006 (illustration can slightly differ for different sizes)
  • Page 3 Sheet No. for Eaton Pressure Filters, Change-Over 69750-4B DA/EDA 106, 256, 406, 636, 1006, related specification Page 3/4 WARNING: Equipment should be shut down and isolated from energy sources and other equipment before any inspection or servicing to prevent risk of shock or process fluid leakage.
  • Page 4 Microglass (VG) or paper (P) filter media CANNOT be cleaned and need to be replaced when it reaches the dirt holding capacity. Wire mesh (G) filter media can be cleaned and used again. Follow the cleaning specification for Eaton filter elements, sheet no. 21070-4 and 39448-4 to clean wire mesh filter media. 6. Pressure difference measuring If the filter assembly includes a clogging indicator, the indicator will measure the pressure difference across the filter element.

This manual is also suitable for:

Da/eda 256Da/eda 406Da/eda 636Da/eda 1006

Table of Contents