Eaton MotoRx Series Instructional Leaflet
Eaton MotoRx Series Instructional Leaflet

Eaton MotoRx Series Instructional Leaflet

9000x series af drives dv/dt filters

Advertisement

Quick Links

Instructional Leafl et IL04012002E
9000X Series AF drives-
MotoRx dV/dt fi lters
Contents
Description
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
MotoRx dV/dt filter kit operation . . . . . . . . . . . . 2
dV/dt filter kits . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Mounting dimensions . . . . . . . . . . . . . . . . . . . . . . 3
Mounting guidelines . . . . . . . . . . . . . . . . . . . . . . . 4
Mounting instructions . . . . . . . . . . . . . . . . . . . . . . 4
Wiring guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ordering information . . . . . . . . . . . . . . . . . . . . . . . 6
ALL ELECTRICAL INSTALLATION AND MAIN-
TENANCE WORK ON THE MOTORX DV/DT
FILTER SHOULD ONLY BE CARRIED OUT BY
QUALIFIED ELECTRICIANS.
Effective September 2009
Page
WARNING!
WARNING!
DO NOT ATTEMPT ANY WORK ON POWERED
UNITS. COMPONENTS AND COMPONENT
BOARDS INSIDE THE ADJUSTABLE FREQUENCY
DRIVE AND MOTORX DV/DT FILTER COM-
PONENTS MAY BE AT INCOMING VOLTAGE
POTENTIAL WHEN THE AFD IS CONNECTED
TO SUPPLY VOLTAGE. COMING IN CONTACT
WITH LIVE COMPONENTS IS EXTREMELY
DANGEROUS AND MAY CAUSE DEATH OR
SERIOUS INJURY.
NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF FITNESS FOR A
PARTICULAR PURPOSE OR MERCHANTABILITY,
OR WARRANTIES ARISING FROM COURSE
OF DEALING OR USAGE OF TRADE, ARE
MADE REGARDING THE INFORMATION,
RECOMMENDATIONS, AND DESCRIPTIONS
CONTAINED HEREIN. In no event will Eaton be
responsible to the purchaser or user in contract,
in tort (including negligence), strict liability or
otherwise for any special, indirect, incidental or
consequential damage or loss whatsoever, includ-
ing but not limited to damage or loss of use of
equipment, plant or power system, cost of capital,
loss of power, additional expenses in the use of
existing power facilities, or claims against the
purchaser or user by its customers resulting from
the use of the information, recommendations, and
descriptions contained herein. The information
contained in this document is subject to change
without notice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MotoRx Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton MotoRx Series

  • Page 1 OF DEALING OR USAGE OF TRADE, ARE MADE REGARDING THE INFORMATION, WARNING! RECOMMENDATIONS, AND DESCRIPTIONS CONTAINED HEREIN. In no event will Eaton be ALL ELECTRICAL INSTALLATION AND MAIN- responsible to the purchaser or user in contract, TENANCE WORK ON THE MOTORX DV/DT...
  • Page 2 Four (4) 5/16-inch flat washers Two (2) 8–32 x 0.75 screws Six (6) 0.25–20 x 0.62 hex screws Six (6) 0.25–20 hex nuts Six (6) 1/4-inch flat washers Six (6) Belleville spring washers Six (6) #2 ring lugs EATON CORPORATION www.eaton.com...
  • Page 3 6.00 (152.4) 5.00 (127.0) MotoRx1000-5075 1.27 (32.3) 1.80 (45.7) 4.33 (110.0) 2.03 (51.6) 3.27 (83.1) 4.95 (125.7) 6.00 (152.4) 5.00 (127.0) MotoRx1000-5100 1.22 (31.0) 2.43 (61.7) 4.86 (123.4) 2.02 (51.3) 2.73 (69.3) 4.05 (102.9) 8.00 (203.2) 5.75 (146.1) EATON CORPORATION www.eaton.com...
  • Page 4 4. Mount the terminal block to the drive housing in a conve- nient location, using two 6–32 x 1 Phillips mounting screws. 5. Affix the terminal block label to the drive housing to indicate the appropriate motor lead locations. EATON CORPORATION www.eaton.com...
  • Page 5 Resistor and Clamp Board Assembly Important: To avoid component failure, clamp board wires must be terminated to the load side of the reactor. dV/dt Clamp Board P BUS To P Bus Figure 6. Wiring the MotoRx dV/dt Filter Kit EATON CORPORATION www.eaton.com...
  • Page 6 010 = 10 hp MotoRx1000-5030 25–30 020 = 20 hp MotoRx1000-5050 40–50 030 = 30 hp 60–75 MotoRx1000-5075 050 = 50 hp 075 = 75 hp MotoRx1000-5100 100 = 100 hp Figure 8. MotoRx dV/dt Filter Kit Ordering Matrix EATON CORPORATION www.eaton.com...
  • Page 7 9000X Series AF drives— Instructional Leafl et IL04012002E MotoRx dV/dt fi lters Effective September 2009 EATON CORPORATION www.eaton.com...
  • Page 8 Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com © 2009 Eaton Corporation PowerChain Management is a registered All Rights Reserved trademark of Eaton Corporation. Printed in USA Publication No. IL04012002E / Z9135 All other trademarks are property of their September 2009 respective owners.

This manual is also suitable for:

Motorx1000-5010Motorx1000-5020Motorx1000-5030Motorx1000-5050Motorx1000-5075Motorx1000-5100

Table of Contents