Eaton DCF-3000 Installation Operation & Maintenance

Eaton DCF-3000 Installation Operation & Maintenance

Advertisement

Quick Links

Description ......................................................................................... 1
Specifications ..................................................................................... 1
Service Requirements ................................................................... 1
Materials of Construction ............................................................... 1
Connections ................................................................................... 1
Elastomers ..................................................................................... 2
Solid Removal Limit ....................................................................... 2
Design Pressures .......................................................................... 2
Design Temperature ...................................................................... 2
Filter Volume.................................................................................. 2
Airborne Noise Emissions ............................................................. 2
Installation .......................................................................................... 2
Transportation................................................................................ 2
Securing to Foundation ................................................................. 2
Connecting to Process Piping ....................................................... 2
Checklist ........................................................................................ 2
Commissioning Procedure ............................................................ 2
Operation ............................................................................................ 3
Operational Modes ............................................................................. 3
Filtering .......................................................................................... 3
Screen Cleaning ............................................................................ 3
Purging .......................................................................................... 3
Inspection, Disassembly & Reassembly ............................................ 3
Spare Parts Lists ........................................................................... 5
Maintenance Schedule .................................................................. 6
Weekly ....................................................................................... 6
Monthly ...................................................................................... 6
Troubleshooting ................................................................................. 6
Symptoms ...................................................................................... 6
Possible Faults .............................................................................. 6
Warranty ............................................................................................. 7
Contacts ............................................................................................. 7

Description

Disc cleaned filter type DCF-3000 filter consists of a cylindrical 316
stainless steel filter screen sealed within a 316 stainless steel filter
vessel. Unfiltered process fluid under pressure enters the filter vessel
through the upper port. The process fluid enters the inside of the filter
screen from above and the filtrate flows through the screen, exiting
the filter vessel through the lower port. Contaminants are trapped on
the inside of the screen. The contaminants are periodically scraped
from the surface of the screen by two cleaning discs assemblies
which travels across the surface of the screen. These contaminants
are deposited in a collection chamber at the bottom of the filter vessel
where they are periodically purged out of the bottom port of the filter
vessel.
WARNING: This filter is a pressure vessel designed to
operate under specific pressure, temperature, and
other engineering parameters. There is a risk of
explosion, process fluid leakage or electrical shock if
the requirements set forth in this Manual are not
followed either during installation, operation, inspection or servicing of
this equipment. Equipment should be shut down and isolated from
energy sources and other equipment before any inspection or servicing
to prevent risk of shock or process fluid leakage. Appropriate PPE
required. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO
DEATH, SEVERE INJURY OR PROPERTY DAMAGE.
Teflon
and Viton
are a trademarks of DuPont™. Nordel™ is a trademark of The Dow Chemical Company. Kynar
®
®
Gylon
is a trademark of Garlock Sealing Technologies LLC.
®
DOM0000007, Revision A
DCF-3000 Installation, Operation & Maintenance
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Specifications

The general specifications for a typical DCF-3000 filter system are:

Service Requirements

Electrical: None or 110-240 V AC 50/60 Hz based on controller type.
Air: Minimum 80 PSIG (5.51 bar), Maximum 116 PSIG (8 bar) at 5.0
cfm (141.5 L/min) clean, dry, non-lubricated air, connection size is ¼"
NPT.

Materials of Construction

All welded and wetted materials are type 316 STAINLESS STEEL.
WARNING: The material selection for this vessel is specified by the
customer. It is the customer's responsibility to ensure material
compatibility with process and environment conditions.
SPECIFICATION OF INCOMPATIBLE MATERIALS MAY LEAD TO
PRODUCT FAILURE, LEAKAGE, DEATH, SEVERE INJURY OR
PROPERTY DAMAGE.

Connections

Process inlet & outlet: 8" 150# ANSI raised face flange (standard) or
option ordered.
Purge: 2" NPTI or option ordered.
DOM0000007
is a trademark of Elf Atochem North America, Inc.
®
Page 1 of 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DCF-3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton DCF-3000

  • Page 1 Specifications Description The general specifications for a typical DCF-3000 filter system are: Disc cleaned filter type DCF-3000 filter consists of a cylindrical 316 stainless steel filter screen sealed within a 316 stainless steel filter Service Requirements vessel. Unfiltered process fluid under pressure enters the filter vessel Electrical: None or 110-240 V AC 50/60 Hz based on controller type.
  • Page 2 DCF-3000 Installation, Operation & Maintenance Elastomers Notice: Isolation/block valves (supplied by others) are Lid actuator rod packing – Urethane, Teflon , Viton and Gylon ® ® ® required on all process connections on the filter unit. Viton are available. ®...
  • Page 3 DCF-3000 Installation, Operation & Maintenance Operation Inspection, Disassembly & Reassembly To service the unit: Isolate from process fluids, from the process air Notice: Do not exceed the normal operating and electric supply by using proper lockout tagout procedures. temperature of the lowest rated component. In most Depressurize unit by opening purge and vent valve in that order and cases this is 200 °F (93 °C).
  • Page 4 The unit should stop moving. If this does not work, lock the unit Figure 2 out and contact Eaton customer service. If unit operates WARNING: Equipment should be shut down and correctly, reset the safety switch and put the unit back online.
  • Page 5 DCF-3000 Installation, Operation & Maintenance Spare Parts Lists Table for Figure 4 - Disc Assembly lower and upper Ref Part Number Description (qty) WER0000014 PLATE ASSY, LOWER MCS-1500 FAB SS6 WER0000013 PLATE ASSY, UPPER MCS-1500 FAB SS6 SCREW, #8-18X1/2 SELF DRILLING...
  • Page 6 Check to see if the filter system is set to the proper Maintenance voltage. To service the DCF-3000 filter unit, isolate it from the process air and Check all wiring connections. electrical supply using proper lockout/tagout plant procedures. No air supply Depressurize and de-energize all sources of power.
  • Page 7 Voice: +65 6825 1668 beyond our control, no guarantee, expressed or implied, is made by Eaton as to the effects of such use or the results to be obtained. Eaton assumes no liability arising out of the Internormen Product Line use by others of such products.

Table of Contents