INTRODUCTION

METRON wall-mounted STANDARD/DUO and floor-mounted TOWER STANDARD/DUO are heavy duty all-metal modular EV charging stations designed for long life
operation with maximum user safety features. They also offer smart charging via Metron proprietary Hardwired or Wireless Dynamic Power Control system, OCPP
module with RFID reader for connecting to any cloud backend platform for payment and energy monitoring, ISO 15118 high level communication module for simple
charging authorization and V2G capability, OTA software updates and more.
STANDARD models offer charging power up to 22 kW (3x32A) and DUO models offer charging power up to 2 x 22 kW (3x32A). All models come with oversized main
charging power contactor with 63A current rating for long life operation (20 years+), modular RCCB device (Type B or Type A with 6mA DC) with 10.000A short circuit
breaking capacity and modular automatic circuit breaker with 10.000A short circuit breaking capacity what ensures not only safest domestic use but also allows the
stations to be installed in industrial areas for commercial use. Modular design ensures on-site repairability in max. 15 minutes. The stations with built-in charging cables
can also be equipped with TESLA remote charge port opener & plug unlocker.
Any other use is not allowed and is regarded as improper use.
Before using the EV charging station, please thoroughly read this manual and follow the instructions provided therein. Please keep the manual for future use. If you
are unsure about the proper usage, please contact the manufacturer or your dealer before usage.

IMPROPER USE

Improper use can lead to property damage or personal injury. In such cases, the manufacturer and retailer accept no liability. Warranty will be voided in case of
improper use. You must not:
• modify / manipulate the EV charging station!
• drive over plugs and cables of the EV charging station!
• draw more than maximum specified charging current from the EV charging station!
• connect unsuitable plugs and cables!
• use the EV charging station if damaged!

GENERAL SAFETY INSTRUCTIONS

• Carefully read this security instructions before using the product!
• Never draw more than maximum specified charging current from the EV charging station!
• Children are not allowed to use the EV charging station.
• Keep animals away while using the EV charging station.
• Avoid liquids entering the EV charging station. Never use the EV charging station if the sockets or plugs are wet.
• Only connect undamaged, designated and labelled plugs & cables to the EV charging station.
Podnart 33, SI-4244 Podnart
www.eauto.si
info@eauto.si
USER MANUAL
+386 51 320 538

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STANDARD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for METRON STANDARD

  • Page 1 V2G capability, OTA software updates and more. STANDARD models offer charging power up to 22 kW (3x32A) and DUO models offer charging power up to 2 x 22 kW (3x32A). All models come with oversized main charging power contactor with 63A current rating for long life operation (20 years+), modular RCCB device (Type B or Type A with 6mA DC) with 10.000A short circuit breaking capacity and modular automatic circuit breaker with 10.000A short circuit breaking capacity what ensures not only safest domestic use but also allows the...
  • Page 2 If hardwired or wireless Metron Dynamic Power Control system that offers smart charging is installed the charging power is dynamically controlled in order to not blow main house fuses; this system is also smartly taking into account the solar / wind / hydro power plant if house has it installed (see chapter “METRON Hardwired or Wireless Dynamic Power Control”...
  • Page 3 Smart EV charging stations marked with “+” have a built-in WiFi access point with web server what enables users to connect to it wirelessly by any smart phone, tablet or laptop PC. As there is a web server inside with preloaded METRON Charge Control application you don’t need to install any additional program / application on your device because the METRON Charge Control simply runs in your favorite web browser (Google Chrome, Microsoft Edge, Mozilla Firefox…) on any operating...
  • Page 4 In case of dynamically controlling 2 or more charging stations this can be done wirelessly only as this greatly reduces laying cables and thus cost. For METRON Wireless Dynamic Power Control all you need is 1 pcs METRON Dynamic EV Charging Unit (model 3FD-3) with clamp-on current sensors. This way up to 150 Metron wall-mounted, floor mounted or even METRON smart portable EV charging stations can be controlled and main fuses with rated currents up to 1000A are supported.
  • Page 5 6/8/10/13/16/20**/25**/ 32**A via front button, “+” models “+” models from 6A in 1A steps to 16A or 32A via from 6A in 1A steps to 16A or 32A via WiFi Metron Charge Possible charging current settings WiFi Metron Charge Control app.
  • Page 6 LIMITED WARRANTY METRON warrants its product to the original consumer purchaser that it will repair, or replace, any product that is determined to be defective for the following terms: Two (2) years from date of purchase on all components. To be eligible for repair or replacement under this warranty, the product in question must be sent back to METRON within the warranty period and the original consumer purchaser must comply with the following conditions: The product thereof must not have been modified or altered in any way by an unauthorized source;...

This manual is also suitable for:

DuoTower standardTower duoStandard+

Table of Contents