All specifications and descriptions contained in this document are verified to be accurate at the time of printing. However, because continuous improvement is a goal at METRON, we reserve the right to make product modifications at any time. To communicate any inaccuracies or omissions in this document, please send an email to: info@eauto.si...
• avoid causing harm to the environment These instructions are an important part of the product and must be retained for future reference. METRON accepts no liability for any damage resulting from non observance of the information in this manual.
The METRON charging station is meant to be used in private and semi-public areas, such as company car parks, depots or private land. The charging station is used exclusively for charging electrically powered vehicles.
About Optional Equipment Depending on the version, the charging station is equipped with one of the following connector systems: Charging socket Type 2 for Mode 3 charging. Permanently connected charging cable with charging connector Type 2. Permanently connected charging cable with charging connector Type 1. Identification Plate Manufacturer Type...
About Exterior And Interior View Lock LED light Push button Socket kWh counter Charging cable fuse Charge control fuse RCCB Circuit braker CB CP terminal Terminal earth charge controler EV Charging station user manual...
About General Data Nano Standar Charging station plug/ Type 2 / Type 1 (IEC Type 2 (IEC 62196) Type 2 (IEC 62196) socket type 62196 / SAE J1772) female plug or charging female plug or charging female plug or type 2...
About Nano Standar IP Rating IP54 IP54 IP54 Weight App 8-10 kg App 8-10 kg App 10-12 kg Dynamic power control Optional *Exact max charging power and configuration information can be found on the product information label, which is located on the right hand side of the charging station.
Installation Warning: Mortal danger posed by improper installation. There is a risk of injury for persons per- forming tasks for which they are neither qualified nor have received appropriate training. • The device may only be installed by personnel which are familiar with the task, have been instructed with regard to the associated hazards and who possess the necessary qualifications.
Installation Unpacking Caution: Damage to the charging station by improper handling. Collisions and impacts may damage the charging station. • Move the charging station with caution. • Use a soft base to set aside the charging station Charging station User manual Warranty Bag with installation hardware (screws, dowels) Opening The Charging Station...
Installation Minimum Distances Maintain the specified minimum distances for unrestricted access during operation, maintenance and repair. The dimensions are given in mm. Installation...
For installation on concrete, brick and wood walls, use the included installation hardware. For other sur- faces, a suitable on-site mounting method must be chosen. METRON recommends the installation of the charging station at a height (up to the top edge of the en- closure) of approximately 1.50 meters above the finished floor.
Electrical connection Voltage Supply / Supply Network Connection Warning: Risk of death by electric shock! Components have voltage applied. Contact with current conducting parts results in an electric shock, burns or death. When working with the electrical system, the following points must be observed: •...
Electrical connection Connecting The Supply Line Strip the supply cable over a length of 370 mm and remove the core insulation over a length of 12 mm Connect the cores of the supply cable to the RCCB ① and the earth core to the terminal ② The protective earth conductor ③...
Operation Warning: Risk of injury There is a risk of injury due to damage to the charging system. If it appears that, the charging system cannot be operated safely: • Take the charging system out of service. • Determine and eliminate any faults / malfunctions. •...
The setting begins automatically when the LED starts to blink again. 1st Group – Current Setting This setting enables you to set the maximum charging current with which your electric vehicle, will be charging. Nano 3,7 kW Nano 7,4 kW Number of blinks...
Operation Duo 11 kW Duo 22 kW Number of blinks Charging 2x3x6 A 2x3x8 A 2x3x10 A 2x3x13 A 2x3x16 A 2x3x20 A 2x3x25 A 2x3x32 A 2x4,1 kW 2x5,5 kW 2x6,9 kW 2x9,0 kW 2x11,0 kW 2x13,8 kW 2x17,4 kW 2x22 kW current/power 2nd Group –...
Operation Example 1: Let say we want the following specifications for our charging station: • 16 A Current Setting = • 32 A Main household fuse type = • On-board charger response time = 5 seconds STEP 1 First, you need to set the on-board charger response time. Press and hold the push button (LED switches off immediately);...
Operation STEP 3 Next is main household fuse type. Press and hold the push button (LED switches off immediately); Releasing the push button after 5th blink determines the setting. Example 2: For this example, we want the following specifications for our charging station: •...
Operation STEP 2 Set main household fuse type. Press and hold the push button (LED switches off immediately); Releasing the push button after 6th blink determines the setting. Important: The dynamic charging control will maintain the desired charging current until the over- all load on the line is greater than setting of the main household fuse type.
Operation Mode 3 Charging Make sure that vehicle and charging cable are suitable for mode 3 charging. Connect the charging cable to the vehicle. Insert the plug of the charging cable completely into the charging socket type 2 at the charging station (only for charging stations with integrated charging socket type 2).
Maintenance Warning: Risk of death resulting from improper maintenance / repair. There is a risk of injury for persons performing tasks for which they are neither qualified nor have received appropriate training. • The maintenance / repair of the device may be performed only by persons who are familiar with this task, have been instructed with regard to the associated hazards and who possess the neces- sary qualifications.
Troubleshooting Warning: If you cannot rectify the error or fault, ask a qualified electrician to check the charging station. Problem Cause LED is not blinking. There is no power to the charging Check the activation of CB or station or EVSE, the LED is faulty or RCCA, check EVSE fuse.
Disassembly, Storage and Disposal Disassembly Warning: Risk of death by electric shock! Components have voltage applied. Contact with current conducting parts results in an electric shock, burns or death. When working with the electrical system, the following points must be observed: •...
All shipping costs regarding repair or replacement of the product is to be pre-paid by the customer. Returning Devices In case you return the device to METRON for repair, please use the original packaging or a suitable, safe trans- port container.
Need help?
Do you have a question about the Nano and is the answer not in the manual?
Questions and answers