2021 Metron Institute All information in this document is subject to copyright and other intellectual property rights of Metron Institute and its licensors. This material may not be modified, reproduced or copied, in whole or in part, without the...
Supply Voltage..............11 Safeguarding and personal protection......11 Connecting the supply line...........12 Operation..........13 Setting the charging current/power via front button..............13 METRON Charge Control application (standard for “+” models)..........14 Dynamic Power Control (OPTIONAL for “+” models)...........16 Mode 3 Charging.............17 Terminating the charging process......17 Status LED and troubleshooting........18...
• avoid causing harm to the environment. These instructions are an important part of the product and must be retained for future reference. METRON accepts no liability for any damage resulting from non-observance of the information in this manual. Safety The device has been designed using state-of-the-art technology and is safe to operate.
Dynamic Power Control system which protects the main household fuse and allow solar SURPLUS charging where the house has a solar power plant installed. The METRON charging station is meant to be used in private and semi-public areas, such as company car parks, depots or private land.
About Charging Connectors Depending on the version, the charging station is equipped with one of the following connector systems: Charging socket Type 2 for Mode 3 charging. Permanently connected charging cable with charging connector Type 2. Permanently connected charging cable with charging connector Type 1. Identification label Manufacturer Type...
Exterior and Interior View Of Typical Charging Station Lock LED indicator Push button Socket (optionally with Type 2/Type 1 plug) METRON Micro EVSE 1 or Micro EVSE 3 charge controller Charge controller power supply fuse Charging fuse Residual current protection device (RCCB) Charging contactor...
Circuit breaker/fuse Residual-current device type B or type A + 6mA DC (FID/RCCB) WiFi Metron Charge standard for “+” models standard for “+” models standard for “+” models Control app. Dynamic Power Control standard for “+”...
Page 9
About Nano(+) Standard(+) Duo(+) Tesla remote for optional for all models optional for all models optional for all models opening charge port with type 2 plug with type 2 plug with type 2 plug and unlocking the plug – integrated in Type 2 plug Supported WiFi IEEE 802.11b/g/n...
Installation Warning: Mortal danger posed by improper installation. There is a risk of injury for persons performing tasks for which they are neither qualified nor have received appropriate training. • The device may only be installed by personnel which are familiar with the task, have been instructed with regard to the associated hazards and who possess the necessary qualifications.
Installation Opening the charging station Insert the key in the keyhole. Turn the key clockwise. When the key is in vertical position, the charging station is unlocked. Open the front panel. Mounting on the wall – minimal distance to devices/obstacles Maintain the specified minimum distances for unrestricted access during operation, maintenance and repair.
A suitable on-site mounting method must be chosen, depending on the installation surface (concrete, brick, wood, etc.). METRON recommends the installation of the charging station at a height (up to the top edge of the casing) of approximately 1.50 meters above the finished floor.
Electrical connection Supply Voltage Warning: Risk of death by electric shock! Components have voltage applied. Contact with current conducting parts results in an electric shock, burns or death. When working with the electrical system, the following procedure must be followed: •...
Electrical connection Connecting the supply line Strip the supply cable over a length of 370 mm and remove the core insulation over a length of 12 mm. Connect the cores of the supply cable to the RCCB ① and the earth core to the terminal ②. The protective earth conductor ③...
Operation Setting the charging current/power via front button Press and hold the push button (blue LED switches off immediately). After 5 seconds LED starts blinking slowly. Releasing the push button after a certain number of blinks determines the setting (see example on page 18). This setting enables you to set the maximum charging current, with which your electric vehicle will be charging.
Go to WiFi menu in your smart phone, tablet or laptop PC and search for WiFi networks. • Find “METRON Station 1” network and connect to it; enter the WiFi password 12345678 (this is default - it is recommended that you change it in the METRON Charge Control application).
Page 17
Energize the charging station and carefully (without touching anything else) press the small tact button marked as “PB1” for 2-3 seconds; WiFi name (ssid) is reset to default value “METRON Station 1” and forgotten password is reset to default value 12345678 but it’s not yet activated.
Operation Dynamic Power Control (OPTIONAL for “+” models) All “+” charging stations can be equipped with METRON Dynamic Power Control system that is always monitoring the load at house main fuse with electric current sensors and dynamically adjusting (lowering or rising) the charging current/power of your electric vehicle in the way the main house fuse never gets overloaded (never blows-up).
Operation Mode 3 Charging Warning: Make sure that vehicle and charging cable are suitable for mode 3 charging. Connect the charging cable to the vehicle. Insert the plug of the charging cable completely into the charging socket type 2 at the charging station (only for charging stations with integrated charging socket type 2).
(plugged in or not plugged in) - Other power devices switched on (water heaters, ovens, washing Only applicable for versions with machines...). Restarts charging automatically when those power METRON Dynamic Power Control consumers are switched off. system. Faults: LED status...
Maintenance Warning: Risk of death resulting from improper maintenance/repair. There is a risk of injury for persons performing tasks for which they are neither qualified nor have received appropriate training. • The maintenance/repair of the device may be performed only by persons who are familiar with this task, have been instructed with regard to the associated hazards and possess the necessary qualifications.
Disassembly, Storage and Disposal Disassembly Warning: Risk of death by electric shock! Components have voltage applied. Contact with current conducting parts results in an electric shock, burns or death. When working with the electrical system, the following points must be observed: •...
All shipping costs regarding repair or replacement of the product is to be pre-paid by the customer. Returning Devices In case you return the device to METRON for repair, please use the original packaging or a suitable, safe transport container.
Need help?