Download Print this page
METRON NANO+ Quick Installation Manual

METRON NANO+ Quick Installation Manual

Smart wall mounted and portable charging stations with wifi
Hide thumbs Also See for NANO+:

Advertisement

Quick Links

SMART wall mounted and portable charging stations with WiFi
NANO+
STANDARD+
&
PC03X+
Micro EVSE 3 charging controller code version (wall mounted stations): v3.04
Micro EVSE 4 charging controller code version (portable stations): v4.01
WiFi METRON Charge Control application version (wall mounted stations): v1.04
WiFi METRON Charge Control application version (portable stations): v2.02
1. Mount the station (4 screws) (applicable for wall mounted stations).
2. Connect the station to 230/400Vac 50Hz (L1, L2, L3, N, PE) power supply (applicable for wall mounted
stations).
3. Apply the power supply and observe the blinking of blue status LED on the front side of the wall mounted or
portable station. The number of blinks indicates the maximum charging power to which the station has been
set (1 blink=6A, 2=8A, 3=10A, 4=13A, 5=16A, 6=20A, 7=25A, 8=32A)
4. Test the functionality of manual charging current setting by pressing the push button on the front panel (blue
status LED OFF) and keep it pressed. After 5 seconds the blue status LED starts to blink (keep it pressed).
Count the number of all blinks. After the last blink the blue status LED will switch OFF and you can release the
button. 16A charging stations maximum number of blinks is 5; 32A versions have all 8 blinks.
5.
Explain to the client
that blinking blue status LED represents charging in progress, status LED ON means that
the vehicle is not connected or charging has already completed.
6.
Explain to the client
that they can set the maximum charging current if they press the button and count the
blue status LED blinks. The set value is saved in to the memory and is stays saved also in case of power loss.
PC04X+
&
QUICK INSTALLATION GUIDE
rev. 4 , 01. 12. 2022- - - applicable for:
OCPP/RFID module code version (wall mounted stations): v1.00
3FD-2 DYNAMIC EV CHARGING UNIT code version: v2.02
www.eauto.si
DUO+ with OCPP
&
PC05X+
&
Page 1
info@eauto.si
+386 51 320 538
RFID
&

Advertisement

loading
Need help?

Need help?

Do you have a question about the NANO+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for METRON NANO+

  • Page 1 OCPP/RFID module code version (wall mounted stations): v1.00 Micro EVSE 4 charging controller code version (portable stations): v4.01 WiFi METRON Charge Control application version (wall mounted stations): v1.04 WiFi METRON Charge Control application version (portable stations): v2.02 3FD-2 DYNAMIC EV CHARGING UNIT code version: v2.02 1.
  • Page 2 • Find “METRON Station 1” (wall mounted stations) or “METRON Portable 1” (portable stations) network and connect to it; enter the WiFi password 12345678 (this is default - it is recommended that you change it in the METRON Charge Control application).
  • Page 3 HARDWIRED 1 or 3-phase MAIN FUSE protection DYNAMIC charging with 1 WALL MOUNTED charging station per fuse 1. After installing the charging station as described on the Page 1 install the supplied current measuring transformers (CT) on the house/building main power supply input and connect them to Micro EVSE 3 DYNAMIC WiFi EV charge controller as shown on the ME3-1 or/and ME3-2 drawings in the attachment.
  • Page 4 5. Test the 3/1-phase main fuse protection dynamic charging: Connect to WiFi and go to the Metron Charge Control web-based application. Connect the electric vehicle to the charging station and observe the charging current measurements in WiFI Charge Control app. under “Advanced info”.
  • Page 5 WIRELESS 1 or 3-phase MAIN FUSE protection DYNAMIC charging with 1 or more WALL MOUNTED charging stations 1. Install the charging station as described on the Page 1. 2. Switch ON charging station power supply. 3. Set the main fuse rating to 35A (needed only if it has been changed - factory default setting is already 35A) via front PUSH BUTTON + status LED blinks as described on Page 3.
  • Page 6 WIRELESS 1 or 3-phase MAIN FUSE protection DYNAMIC charging with 1 or more PORTABLE charging stations 1. Connect the portable charging station to wall socket (apply the power supply). 2. Set the needed parameters via front PUSH BUTTON: when no car is connected push the charging station front button (blue status LED is switched OFF) and keep it pressed.
  • Page 7 INSTALLING 3FD-2 DYNAMIC EV CHARGING UNIT for 1 or 3- phase MAIN FUSE protection WIRELESS DYNAMIC charging of up wall mounted and portable charging stations per main fuse 1. Activate wireless FUSE protection DYNAMIC charging on wall mounted station(s) (default setting is “wireless off”) as described on Page 3 (portable stations have enabled wireless dynamic charging RF receiver by default).
  • Page 8 1 or more portable stations powered from the same main fuse! 6. Test the 3/1-phase wireless main fuse protection dynamic charging: Connect to WiFi and go to the Metron Charge Control application on one of the wirelessly controlled charging stations. Connect the electric vehicle to the charging station and observe the charging current measurements in WiFI Charge Control app.
  • Page 9 3FD-2 DYNAMIC EV CHARGING UNIT distributes the charging power to all wirelessly controlled charging stations equally. However, the client can still adjust the charging power on each station via front button or via current setting slider in WiFi Metron Charge Control application. Explain to the client that in case of wirelessly controlling only one (1) charging station it will automatically reduce charging power or stop the charging in case of main fuse overload.
  • Page 10 ATTACHMENTS Mark Type Description Revison ME3-1 Drawing 3-phase MAIN FUSE protection DYNAMIC charging with 1 wall mounted charging station per main fuse – HARDWIRED option ME3-2 Drawing 1-phase MAIN FUSE protection DYNAMIC charging with 1 wall mounted charging station per main fuse – HARDWIRED option 3FD-2-4 Drawing 3-phase MAIN FUSE protection DYNAMIC charging with 1 or more wall...
  • Page 11: Electric Vehicle

    INSTALATION OF METRON Micro EVSE 3 DYNAMIC WiFi based WALL MOUNTED CHARGING STATION for 3-phase DYNAMIC MAIN FUSE PROTECTION CHARGING of ONE (1) electric vehicle HARDWIRED OPTION 3f GRID 400V/50Hz GRID TIE PV inverter CHARGING STATION L1 L2 EV CHARGE CONTROLLER...
  • Page 12 INSTALATION OF METRON Micro EVSE 3 DYNAMIC WiFi based WALL MOUNTED CHARGING STATION for 1-phase DYNAMIC MAIN FUSE PROTECTION CHARGING of ONE (1) electric vehicle HARDWIRED OPTION 1f GRID 230V/50Hz GRID TIE PV inverter CHARGING STATION EV CHARGE CONTROLLER MODEL: Micro EVSE 3 DYNAMIC WiFi...
  • Page 13: Electric Vehicles

    DISTRIBUTION PANEL solar SURPLUS electric vehicle charging (S1 closed = solar SURPLUS charging) S1 mounting location: anywhere NOTE: Solar SURPLUS charging can also be activated via WiFi Metron Charge Control app. Station ID: 2 DYNAMIC EV CHARG ING UNIT MODEL: 3FD-2 www.eauto.si...
  • Page 14 DISTRIBUTION PANEL solar SURPLUS electric vehicle charging (S1 closed = solar SURPLUS charging) S1 mounting location: anywhere NOTE: Solar SURPLUS charging can also be activated via WiFi Metron Charge Control app. Station ID: 2 DYNAMIC EV CHARG ING UNIT MODEL: 3FD-2 www.eauto.si...

This manual is also suitable for:

Standard+Duo+RfidPc03x+Pc04x+Pc05x+